Industrial 4 Port USB Hubs
Models UHR204 & UHR304
1.
Unpack the USB hub from the shipping container.
Verify that all included items are present.
Note: There is no software CD for this product. It
will install as a Generic USB Hub and does not
require additional drivers.
2.
Mount the product via the included DIN clip or included
Panel Mount adapter kit. See the Mounting section for
more information.
3.
Using the included USB cable, connect one end of the
cable to the Host PC or upstream USB hub. Plug the
other end of the cable into the USB hub via the port
marked USB Host.
Note: If the USB upstream device is capable of
supplying power to the Hub, then the Bus Power
LED will light. When Local (external) power is
applied to the terminal block or the barrel jack the
Local Power LED will light. The Local Power LED
will light only when power is applied externally and
an active upstream connection is made (normally
needs 500mA from host minimum).
4.
Ground the hub to earth ground using the green ground
screw.
5.
Add power via the terminal block or barrel jack if one of
the following instances will occur:
Power Scenario 1
The USB hub is connected to an upstream port that
does not offer full power out. (Example: connecting the
B&B hub into another hub that is not externally powered
Power Scenario 2
The USB Hub will have another USB hub connected to
one of its downstream ports.
Power Scenario 3
The USB Hub will have bus powered devices plugged
into it. (Example: using a B&B USB to serial device that
uses the USB bus for power.)
LED
Type
State Description
Bus
Power
On
Product is plugged into an active host device
and local power is not applied (the product
can supply up to 100mA per downstream
power)
Off
Product has local power applied or no power
present
Local
Power
On
Local power is applied and an active host
connection is made (the product is capable
of supplying 500mA per downstream port)
Off
Product is Bus powered or no power present
Port
LED's
On
Port is Active and ready for use
Off
Port has a fault - power may need to be
cycled
LED
Type
State Description
Power
On
Power is applied (the product is capable of
supplying 500mA per downstream port)
Off
Power is not applied
Port
LED's
On
Port is Active and ready for use
Off
Port has a fault - power may need to be
cycled