7 - MAINTENANCE
Every 500 hours
Change engine oil and filter
Change the engine oil and filter when the hour meter registers 500 hours Change the engine oil and filter every 500
hours thereafter or more frequently when the engine operating conditions are severe.
Prior operation:
Keep all unauthorized personnel clear of the area. Park the machine on level ground, in neutral with the parking
brake applied, and the attachment lowered to the ground. Make sure that all residual pressure is relieved from circuits
before beginning maintenance.
Service specifications
Type of oil
CASE AKCELA UNITEK NO. 1™ SBL CJ-4 SAE
10W-40
Capacity (with filter change)
16.4 l
(
17.3 US qt
)
Capacity (without filter change)
15.6 l
(
16.5 US qt
)
1. Open the left-hand front access door. Secure the ac-
cess door with the door strut.
2. Remove the oil dipstick
(1)
.
RAIL13DOZ1693AA
1
NOTE:
Oil drains faster when the oil is warm (but not hot) and the oil dipstick is removed.
3. Use a suitable container to collect the drained oil.
4. Remove the bolts that secure the engine oil access
plate under the engine.
RAPH12DOZ0095AA
2
NOTE:
If the machine is so equipped, and the special draining equipment is available, use the engine environmental
drain located in the left side engine access door.
7-58
Содержание 2050M
Страница 22: ...1 GENERAL INFORMATION 1 16 ...
Страница 106: ...4 OPERATING INSTRUCTIONS 21 Check the controls for correct operation 4 4 ...
Страница 136: ...5 TRANSPORT OPERATIONS 5 14 ...
Страница 196: ...7 MAINTENANCE RAIL13DOZ1597GA 1 7 40 ...
Страница 197: ...7 MAINTENANCE RAIL13DOZ1598GA 2 7 41 ...
Страница 198: ...7 MAINTENANCE RAIL13DOZ0003GA 3 7 42 ...
Страница 242: ...7 MAINTENANCE 12 Close and lock the right hand side front access panel RAIL13DOZ0776AA 12 7 86 ...
Страница 264: ...7 MAINTENANCE RAIL12DOZ1024FA 2 7 108 ...
Страница 265: ...7 MAINTENANCE RAIL13DOZ1526GA 3 7 109 ...
Страница 267: ...7 MAINTENANCE Key Fuse function Amperage 7 Ignition 24V 50 A 8 Telematics 10 A 9 UCM 20 A 10 SCR 20 A 7 111 ...