4 - OPERATING INSTRUCTIONS
Adjusting maximum hydrostatic drive speed
parameter
To adjust the maximum drive speed, follow the same steps
as for steering sensitivity, then highlight “Max Spd”.
The max drive speed choices are: 9, 11, 13, 15 as se-
lected by the operator, with the default speed set to 15.
The speed can be raised or lowered with the speed but-
tons located on the left joystick.
Adjusting reverse speed ratio differential
setting
To adjust the reverse speed ratio differential, follow the
same steps as for steering sensitivity, then highlight
“RevSpdDiff”.
The RevSpdDiff choices are: -2, -1, 0, +1, +2, +3, and +4.
After selecting and highlighting the desired value, press
the enter switch to confirm the selection. Press the es-
cape switch to store the choice.
This will produce a reverse speed calculated from the for-
ward speed. For example, if “+4” is selected, this will pro-
duce a reverse speed 4 speeds higher than the forward
speed. If “-2” is selected, this will produce a reverse speed
2 speeds slower than the forward speed. If “0” is selected,
the reverse and forward speeds will be the same.
The reverse speed cannot be below 1 and above the “Max
Spd” setting.
Adjusting shuttle parameter
To adjust the shuttle parameter, follow the same steps and
highlight “Shuttle”.
The shuttle choices are:
• Smooth
• Moderate (preset from the factory)
• Aggressive
After selecting and highlighting the desired value, press
the enter/escape switch to confirm the selection. Press
the escape switch to store the choice.
Dual function deceleration or transmission
pedal
The deceleration or transmission pedal can be changed
at the transmission selection.
Highlight “Pedal”, and follow the same steps as for
steering sensitivity. Choose between:
• Decel
• Trans-(factory default)
4-17
Содержание 2050M
Страница 22: ...1 GENERAL INFORMATION 1 16 ...
Страница 106: ...4 OPERATING INSTRUCTIONS 21 Check the controls for correct operation 4 4 ...
Страница 136: ...5 TRANSPORT OPERATIONS 5 14 ...
Страница 196: ...7 MAINTENANCE RAIL13DOZ1597GA 1 7 40 ...
Страница 197: ...7 MAINTENANCE RAIL13DOZ1598GA 2 7 41 ...
Страница 198: ...7 MAINTENANCE RAIL13DOZ0003GA 3 7 42 ...
Страница 242: ...7 MAINTENANCE 12 Close and lock the right hand side front access panel RAIL13DOZ0776AA 12 7 86 ...
Страница 264: ...7 MAINTENANCE RAIL12DOZ1024FA 2 7 108 ...
Страница 265: ...7 MAINTENANCE RAIL13DOZ1526GA 3 7 109 ...
Страница 267: ...7 MAINTENANCE Key Fuse function Amperage 7 Ignition 24V 50 A 8 Telematics 10 A 9 UCM 20 A 10 SCR 20 A 7 111 ...