7 - MAINTENANCE
Clean in-line Diesel Exhaust Fluid (DEF) supply filter (Initial)
Clean the in-line supply filter when the machine is new and the hour meter registers 100 hours. Clean every 1500
hours thereafter or more often if conditions so require. The supply line has a small mesh filter within the line.
Prior operation:
Keep all unauthorized personnel clear of the area. Park the machine on level ground, in neutral with the parking
brake applied, and the attachment lowered to the ground. Make sure that all residual pressure is relieved from circuits
before beginning maintenance. Turn the electronic disconnect to the OFF position.
1. Open the rear left hand access compartment, and lo-
cate the DEF supply module.
RAIL13DOZ1702AA
1
2. Remove the bolts holding the supply module in place,
and tilt the module up.
RAIL12DOZ0189AA
2
3. Locate the DEF supply line filter directly below the sup-
ply module.
4. Use a suitable container to catch any DEF fluid that is
discharged during line and filter disassembly. Clean the
area before disassembly.
5. Disconnect the DEF supply line by squeezing the tabs
on the connection and separate the lines.
RAIL12DOZ0191AA
3
7-52
Содержание 2050M
Страница 22: ...1 GENERAL INFORMATION 1 16 ...
Страница 106: ...4 OPERATING INSTRUCTIONS 21 Check the controls for correct operation 4 4 ...
Страница 136: ...5 TRANSPORT OPERATIONS 5 14 ...
Страница 196: ...7 MAINTENANCE RAIL13DOZ1597GA 1 7 40 ...
Страница 197: ...7 MAINTENANCE RAIL13DOZ1598GA 2 7 41 ...
Страница 198: ...7 MAINTENANCE RAIL13DOZ0003GA 3 7 42 ...
Страница 242: ...7 MAINTENANCE 12 Close and lock the right hand side front access panel RAIL13DOZ0776AA 12 7 86 ...
Страница 264: ...7 MAINTENANCE RAIL12DOZ1024FA 2 7 108 ...
Страница 265: ...7 MAINTENANCE RAIL13DOZ1526GA 3 7 109 ...
Страница 267: ...7 MAINTENANCE Key Fuse function Amperage 7 Ignition 24V 50 A 8 Telematics 10 A 9 UCM 20 A 10 SCR 20 A 7 111 ...