7 - MAINTENANCE
9. Remove the bolts and the cover from the right rear ac-
cess panel.
RAIL12DOZ0177AA
3
10. Remove the hydrostatic drive filter
(2)
. Turn the filter
counter clockwise to remove.
11. Clean the contact surface on the filter head. Make
sure that all dirt and gasket material has been re-
moved.
12. Apply a thin coat of clean oil to the hydrostatic oil gas-
ket and threads.
RAIL12DOZ0178AA
4
13. Install and tighten the hydrostatic filter firmly to the fil-
ter head by hand. Do not use a filter wrench to tighten
the filters.
14. Install the reservoir filler cap.
15. Start the engine and run at
1000 RPM
. Check for leak-
age around the filters.
16. Replace all panels and close all access doors se-
curely.
17. Operate the controls several times to remove any air
in the lines.
18. Place the attachments on the ground and stop the
engine. Check the hydraulic oil level.
19. If it is necessary to top off with more oil make certain all
pressure is relieved in the system. Remove the fill cap
slowly to release pressure in the reservoir, and add
T
UTELA
A
UTO
S
UPREME
™ E
NGINE OIL
SAE 10W-30
.
RAIL12DOZ0179AA
5
NOTICE:
Check filters for metal filings or other foreign particles or have oil checked by your authorized dealer through
the Systemguard Lubricant Analysis program.
7-49
Содержание 2050M
Страница 22: ...1 GENERAL INFORMATION 1 16 ...
Страница 106: ...4 OPERATING INSTRUCTIONS 21 Check the controls for correct operation 4 4 ...
Страница 136: ...5 TRANSPORT OPERATIONS 5 14 ...
Страница 196: ...7 MAINTENANCE RAIL13DOZ1597GA 1 7 40 ...
Страница 197: ...7 MAINTENANCE RAIL13DOZ1598GA 2 7 41 ...
Страница 198: ...7 MAINTENANCE RAIL13DOZ0003GA 3 7 42 ...
Страница 242: ...7 MAINTENANCE 12 Close and lock the right hand side front access panel RAIL13DOZ0776AA 12 7 86 ...
Страница 264: ...7 MAINTENANCE RAIL12DOZ1024FA 2 7 108 ...
Страница 265: ...7 MAINTENANCE RAIL13DOZ1526GA 3 7 109 ...
Страница 267: ...7 MAINTENANCE Key Fuse function Amperage 7 Ignition 24V 50 A 8 Telematics 10 A 9 UCM 20 A 10 SCR 20 A 7 111 ...