B.3 Parameter Table
B.3 Parameter Table
♦ A: Initialization Parameters
The A parameter group creates the operating environment for the drive. This includes the parameter Access Level, Motor
Control Method, Password, User Parameters and more.
■ A1: Initialization Parameters
No.(Addr.)
Name
A 1-00
(100H)
<1>
Language Selection
A1-01
(101H)
A ccess L evel Selection
A 1-02
(102H)
<1>
Control Method Selection
A 1-03
(103H)
Initialize Parameters
A 1-04
(104H)
Password
A 1-05
(105H)
Password Setting
Description
Setting
Page
English
Japanese
German
French
Italian
Spanish
Portuguese
Chinese
Default: 0
Min: 0
Max: 7
View and set A1-01 and A 1-04. U D - П П parameters can also be viewed.
User Parameters (access to a set o f parameters selected by the user, A 2-01 to A 2-32)
Advanced A ccess (access to v ie w and set all parameters)
Default: 2
Min: 0
Max: 2
134
V /f Control
Open Loop Vector Control
Closed Loop Vector Control
Closed Loop Vector Control for PM Motors
Default: 0
Min: 0
Max: 7
0: N o initialization
1110: User Initialize (parameter values must be stored using parameter o2-03)
2220: 2-wire initialization
5550: oPE04 error reset
Default: 0
Min: 0
Max: 5550
W hen the value set into A 1-04 does not match the value set into A 1-05, parameters A1-01
through A 1-03, and A2-01 through A 2-33 cannot be changed.
Default: 0000
Min: 0000
Max: 9999
134
134
135
136
<1> Param eter setting value is not reset to the default value when the drive is initialized.
■ A2: User Parameters
No.(Addr.)
Name
|
Description
Setting
Page
A2-01 to
A 2-32
(106 to 125H)
User Parameters 1 to 32
i
P
с
arameters that
ppear here for q
were recently edited are listed here. The user can also select parameters to
uick access.
Default: <5>
Min: A 1-00
Max: o4-16
138
A 2-33
(126H)
User Parameter Automatic
Selection
1
0
1
1
: Parameters A
: Save history o
7 through A2-3
И
Н
Н
^
Н
И
Н
И
Щ
И
Н
i
2-01 through A 2-32 are reserved for the user to create a list o f User Parameters.
f recently view ed parameters. Recently edited parameters w ill be saved to A 2-
2 for quick access.
Default: 1
Min: 0
Max: 1
138
<5> D efault setting is determined by the control mode (A 1-02).
♦ b: Application
Application parameters configure the source of the Up/Down command, timer functions, the Dwell function, the Droop
Control function, Energy Savings, and a variety of other application-related settings.
324