8.2 Drive Options and Peripheral Devices
8.2
Drive Options and Peripheral Devices
The following table of peripheral devices lists the names of the various accessories and options available for Yaskawa
drives. Contact Yaskawa or your Yaskawa agent to order these peripheral devices.
• Peripheral Device Selection: Refer to the Yaskawa catalog for selection and part numbers.
• Peripheral Device Installation: Refer to the corresponding option manual for installation instructions.
Table 8.1 Available Peripheral Devices
Option
|
Model Number
|
Description
P ow er O ptions
DC Reactor
-
Improves the power factor by suppressing harmonic distortion from the power
supply.
AC Reactor
-
Protects the drive when operating from a large power supply and improves the
power factor by suppressing harmonic distortion. Highly recommended for power
supplies that exceed 600 kVA.
Braking Unit
CDBR Series
External braking transistor
Inp u t / O u tp u t O ption C ards
Analog Monitor
A O-A3
Provides extra multi-function analog output terminals.
Output channels: 2
Output voltage: -10 to 10 V, 11 bit (signed)
Digital Input
DI-A3
U sed to set the speed reference by digital inputs
Input channels: 18 (including SET signal and SIGN signal)
Input signal type: BC D 16 bit (4 digit), 12 bit (3 digit), 8 bit (2 digit)
Input signal: 24 Vdc, 8 m A
Digital Output
DO-A3
Provides extra insulated multi-function digital outputs.
Photocoupler relays: 6 (48 V, up to 50 m A )
Contact relays: 2 (250 Vac/up to 1 A, 30 Vdc/up to 1 A )
M otor Speed F eed back O ption Cards
Complementary Signal Encoder
PG-B3
For speed feedback input by connecting a motor encoder
Input: 3 track (can be used with one or two tracks), for HTL encoder connection,
50 kHz max
Output: 3 track, open collector
Encoder power supply: 12 V, max current 200 mA
Line Driver Encoder
PG-X3
For speed feedback input by connecting a motor encoder
Input: 3 track (can be used with one or tw o tracks), line driver, 300 kHz max
Output: 3 track, line driver
Encoder power supply: 5 V or 12 V, m ax current 200 m A
EnDat Encoder
PG-F3
Encoder type: EnDat 2.1/01, EnDat 2.2/01 (HEIDENHAIN), EnDat 2.2/22
(Software version:7016 and later)
Note: Hiperface is under development.
Maximum input frequency: 50 kHz
Pulse monitor: Matches R S-422 level
Output voltage: 5 V ±5%, 8 V ±10%
Maximum output current: 200 mA
Wiring length: 20 m max. for the encoder, 30 m max. for the pulse monitor
E R N 1387 Encoder
PG-E3
Encoder type: E R N 1387 (HEIDENHAIN)
Maximum input frequency: 50 kHz
Pulse monitor: Matches R S-422 level
Output voltage: 5 V ±5%
M aximum output current: 200 mA
Wiring length: 20 m max. for the encoder, 30 m max. for the pulse monitor
C om m un ication O ptions C ards
CANopen
SI-S3
Connects to a CANopen network
Interface O ptions
LED Operator
JVOP-182
5-digits LED operator; max. cable length for remote usage: 3 m
Remote Operator Cable
W V 001/W V 003
Extension cable (1 m or 3 m) to connect the digital operator for remote operation
RJ-45, 8 pin straight through, UTP CAT5e cable
U SB Copy Unit
JVOP-181
A llow s the user to copy and verify parameter settings between drives. Can also be
used as an adapter to connect the drive to the U SB port on a PC.
M ech anical O ptions
NEM A 1 Kit
EZZ020787
Parts to make the drive conform to NEM A Type 1 enclosure requirements
Installation Support Set A
EZZ020642A
For installing the digital operator keypad on the outside o f an enclosure panel that
houses the drive. A lso refer to D ig ita l O perator R em o te Installation on p a g e 3 7 .
Installation Support Set B
EZZ020642B
Others
24 V Power Supply
200 V class: PS-A10LB
400 V class: PS-A10HB
Option to supply the drive controller with 24 Vdc power during main power loss
PC Softw are Tools
DriveWizard Plus
| Contact Yaskawa
| PC tool for drive setup and parameter management
294