5.8 L: Protection Functions
Setting 3: Vector m otor (speed range fo r constant torque: 1:100)
Use this setting when operating a drive-dedicated motor that allows constant torque in a speed range o f 1:100. This motor
type is allowed to run with 100% load from 1% up to 100% speed. Running slower speeds with full load can trigger an
overload fault.
Overload Tolerance
Cooling Ability
Overload Characteristics
Rated Speed=100% Speed
A: Max. speed for 200LJ and above
B: Max. speed for 160MJ to 180 LJ
C: Max. speed for 132MJ and below
100120 167200
Speed (%)
Motor is designed to effectively cool itself at ultra-
low speeds.
Continuous operation with 100% load from 0.5 H z to
50 Hz.
C
Setting 5: Constant torque PM motors (constant torque range of 1:500)
Sets protection characteristics needed when driving a PM with constant torque. These motors allow for a speed control
from 0.2% to 100% when operating with 100% load. Slower speeds with 100% load will trigger overload.
Overload Tolerance
Cooling Ability
Overload Characteristics
Motor is designed to effectively cool itself at ultra-
low speeds (about 0.2% o f base speed).
Continuous operation with 100% load from 0.2% to
100% o f base speed.
P e r c e n t o f b a s e s p e e d (% )
190