5.7 H: Terminal Functions
Setting 30: During torque limit
Output closes when the motor is operating at the torque limit specified by the L7-D D parameters or an analog input.
This setting can only be used in OLV, CLV and CLV/PM control modes. Refer to
L7-01 to L7-04: Torque Limits on
page 198
for details.
Setting 33: Within position lock bandwidth
Output closes when the motor rotor position is within the position lock bandwidth (S3-04) during Position Lock at start
or stop.
Setting 37: During frequency output
Output closes when the drive is outputting a frequency.
Status
Description
Open
Drive is stopped or one o f the follow ing functions is being performed: baseblock, DC Injection Braking, Short Circuit Braking.
Closed
Drive is outputting frequency.
F ig u r e 5 .2 8 D u rin g F r e q u e n c y O u tp u t T im e C h a rt
Setting 47: Input phase loss
This terminal closes when input phase loss is detected.
Setting 4E: Braking transistor fault (rr)
Output closes when the built-in braking transistor in the drive overheats and the (rr) error is detected.
Setting 50: Brake control
This setting can be used in the brake sequence for the elevator application. Closing the output terminal should cause the
brake to release, and opening the terminal should apply the brake. Refer to
Brake Sequence on page 110
for details.
Setting 51: Output contactor control
Assigning this command to an output terminal can send a signal to the controller to close the output contactor. The output
contactor should open when the terminal is released.
Setting 52: Door zone reached
Terminals closes to indicate that the door zone speed level (L4-13) has been reached, and that controller should open the
car door.
Setting 53: Not zero speed
Output closes as long as the drive is not operating at the zero speed level. Terminal opens when zero speed is reached.
Setting 54: Light load direction
Indicates the light load direction detected during emergency operation with light load search. When the terminal is closed
the light load direction is up, when it is open the light load direction is down. Refer to
Light Load Direction Search
Function on page 124
for details.
Setting 55: Light load direction detection status
This terminal is open during Light Load Direction Search. When the search function is complete, the terminal closes.
Refer to
Light Load Direction Search Function on page 124
for details.
182
YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual