B.3 Parameter Table
No. (Addr.)
Name
Description
Setting
Page
S5-03
(6A DH )
Short Floor M inimum Constant
Speed Time
Sets the minimum operation time when the Advanced Short Floor function is enabled (S5-01
2).
Default: 0.0 s
Min: 0.0 s
Max: 2.0 s
S5-04
(6A EH )
Distance Calculation Acceleration
Time Gain
Set for acceleration jerk compensation in Distance Calculation.
Default: 150.0%
Min: 50.0%
Max: 200.0%
S5-05
(6AFH)
Distance Calculation Deceleration
Time Gain
Set for deceleration jerk compensation in Distance Calculation.
Default: 150.0%
Min: 50.0%
Max: 200.0%
CLV
■
CLV/PM
S5-10
(6B0H)
Stopping Method Selection
Disabled
Direct Landing
Leveling Distance Control
Default: 0
Min: 0
Max: 2
229
S5-11
(6B1H)
Deceleration Distance
CLV
■
CLV/PM
Sets the deceleration distance when Stop Distance Control is enabled
Default: 0 mm
Min: 0 mm
Max: 32767 mm <36>
229
S5-12
(6B2H)
Stop Distance
CLV
■
CLV/PM
Sets the stopping distance w hen Stop Distance Control is enabled.
Default: 0 mm
Min: 0 mm
Max: 10000 mm <37>
230
S5-13
(6D6H)
Direct Landing M inimum Speed
Level
CLV
■
CLV/PM
Sets the speed level for the start o f Direct Landing.
Direct Landing is essentially disabled if the starting speed for Direct Landing is less than the
maximum output speed m ultiplied by this parameter (E1-04
x
S5-13).
Default: 20%
Min: 0%
Max: 100%
230
<36> W hen the length units are set for inches (o1-12 = 1), the setting range becomes 0.00 to 650.00 inches.
<37> W hen the length units are set for inches (o1-12 = 1), the setting range becomes 0.00 to 393.00 inches.
■ S6: Error Detection
No. (Addr.)
Name
Description
Setting
Page
S6-01
(6B3H)
Motor Contactor Response Error
(SE1) D etection/Reset Selection
D etect during stop, SE1 must be manually reset
D etect during stop, SE1 can be automatically reset
N o SE1 detection
Default: 0
Min: 0
Max: 2
S6-02
(6B4H)
Starting Current Error (SE2)
Detection D elay Time
CLV
■
CLV/PM
Sets a delay time for detecting SE2.
Default: 200 ms
Min: 0.00 ms
Max: [S1-04]-[S1-06]
S6-04
(6B6H)
Output Current Error (SE3)
Detection D elay Time
CLV
■
CLV/PM
Sets a delay time for detecting SE3.
Default: 200 ms
Min: 0 ms
Max: 5000 ms
230
S6-05
(6B7H)
Brake Response Error (SE4)
Detection Time
Sets a delay time for detecting SE4.
Default: 500 ms
Min: 0 ms
Max: 10000 ms
230
S6-10
(6B8H)
Overacceleration Detection Level
CLV
■
CLV/PM
If the elevator car accelerates at an abnormal rate, the drive triggers an overspeed fault (dv6)
and has the motor coast to stop. Parameter S6-10 determines the acceleration rate that triggers a
fault.
Default: <7>
Min: 0.0 m /s2
Max: 20.0 m /s2 <7>
231
S6-11
(6B9H)
Overacceleration Detection Time
CLV
■
CLV/PM
Sets a primary delay for detecting overacceleration.
Default: 50 ms
Min: 0 ms
Max: 5000 ms
S6-12
(6BA H )
Overacceleration Detection
Selection
CLV
В
CLV/PM
0: A lw ays enabled
1: During run only
Default: 0
Min: 0
Max: 1
231
S6-15
(6BBH )
Speed Reference Loss Detection
Enabled or disables detection for speed reference m issing (FrL).
0: Disabled
1: Enabled
Default: 1
Min: 0
Max: 1
S6-16
(6BCH)
Restart after Baseblock Selection
0: N o restart after B aseblock/Safe Torque-Off
1: Restart after B aseblock/Safe Torque-Off
Default: 0
Min: 0
Max: 1
231
<7> D efault setting value is determined by the digital operator display unit selection (o1-03). The default is norm ally 1.5 m/s2, but when o1-03 = 6,
the default becomes 5.0 ft/s2 (Setting Range: 0.0 to 50.0 ft/s2).
227
227
227
V/f
V/f
V/f
V/f
230
V/f
230
V/f
V/f
V/f
231
V/f
231