5.10 o: Operator Related Settings
■ o1-21: Roping Ratio
Sets the roping ratio.
No.
Name
Setting Range
Default
o1-21
Roping Ratio
1 to 4
2
Setting 1: 1: 1
Setting 2: 1: 2
Setting 3: 1: 3
Setting 4: 1: 4
■ o1-22: Mechanical Gear Ratio
Sets the gear ratio o f the mechanical gear.
No.
Name
Setting Range
Default
o1-22
Mechanical Gear Ratio
0.10 to 50.00
Determined by A 1-02
♦ o2: Digital Operator Keypad Functions
These parameters determine the functions assigned to the operator keys.
■ o2-01: LO/RE (LOCAL/REMOTE) Key Function Selection
Parameter o2-01 determines whether the LO/RE key on the digital operator will be enabled or not for switching between
LOCAL and REMOTE.
No.
Name
Setting Range
Default
o2-01
LO/RE Key Function Selection
0 or 1
0
Setting 0: Disabled
The LO/RE key is disabled.
Setting 1: Enabled
The LO/RE switches between LOCAL and REMOTE operation. Switching is possible during stop only. When LOCAL
is selected, the LED indicator on the LO/RE key will light up.
■ o2-02: STOP Key Function Selection
Determines if the STOP key on the digital operator can still be used to stop drive operation when the drive is being
controlled from a remote source (i.e., not from digital operator).
No.
Name
Setting Range
Default
o2-02
STOP Key Function Selection
0 or 1
0
Setting 0: Disabled
Setting 1: Enabled
The STOP key will terminate drive operation even if the Up/Down command source is not assigned to the digital
operator. Cycle the Up/Down command to restart the drive if the drive has been stopped by pressing the STOP key.