4.3 The Drive and Programming Modes
♦ Verifying Parameter Changes: Verify Menu
The Verify Menu lists edited parameters from the Programming Mode or as a result o f Auto-Tuning. The Verify Menu
helps determine which settings have been changed, and is particularly useful when replacing a drive. If no settings have
been changed, the Verify Menu will read “None”. The Verify Menu also allows users to quickly access and re-edit any
parameter settings that have been changed.
Note: The Verify M enu will not display param eters from the A1 group (except for A 1-02) even i f those param eters have been changed
from their default settings.
The following example is a continuation o f the steps above. Here, parameter C1-02 is accessed using the Verify Menu,
and is changed again from 1.50 s to 2.50 s.
The steps below are an example o f how to check the list o f edited parameters:
Step
Display/Result
1.
Turn on the power to the drive. The initial display appears.
- MODE - DRV Rdy
Speed Ref (OPR)
U1-01= 0.00%
U1-02= 0.00% IRSEQI
U1-03=
0
.
00
A IlrefI
^ ^ B FWD ^ ^ B
2.
Press
^
or
until the display shows the top o f the Verify Menu.
- MODE -
PRG
Modified Consts
Modified
X Parameters
п г а т а
fw d
1ДАЛД
3.
Press
to enter the list o f parameters that have been edited from their original default settings.
I f parameters other than C1-02 have been changed, use
^
or
^
to scroll until C1-02 appears.
- VERIFY - PRG Rdy
Decel Ramp 1
В И Я З = 2.50sec
(0.0-600.00)
“1.50sec”
l!M.'.?J FWD П А Л Л
4.
Press
J b
to access the setting value. Left digit flashes.
- VERIFY PRG Rdy
Decel Ramp 1
C1-Я1=ЯЯ2.5Яsec
(Я.Я~6ЯЯ.ЯЯ)
“1.50sec”
l!M.'.fJ FWD П А Й Л
YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual