5.4 d: Reference Settings
■ d1-20, d1-21, d1-22: Intermediate Speeds 1 to 3
Sets intermediate speeds 1 through 3.
No.
Name
Setting Range
Default
d1-20
Intermediate Speed 1
0.00 to 100.00% <1>
0.00% <1>
d1-21
Intermediate Speed 2
0.00 to 100.00% <1>
0.00% <1>
d1-22
Intermediate Speed 3
0.00 to 100.00% <1>
0.00% <1>
<1> Setting ranges and defaults vary by the setting units determined by param eter o1-03. Refer to
Defaults and Setting Ranges by D isplay U nit
Selection (o1-03) on page 365
for details.
■ d1-23: Releveling Speed
Sets the releveling speed when a multi-function input terminal is programmed for “Releveling speed” (H1-DD = 52).
No.
Name
Setting Range
Default
d1-23
Releveling Speed
0.00 to 100.00% <1>
0.00% <1>
<1> Setting ranges and defaults vary by the setting units determined by param eter o1-03. Refer to
Defaults and Setting Ranges by D isplay U nit
Selection (o1-03) on page 365
for details.
■ d1-24: Inspection Operation Speed
Sets the inspection speed when a multi-function input terminal is programmed for “Inspection speed” (H1-DD = 54). A
description of the inspection speed can be found in
Inspection Operation on page 109.
No.
Name
Setting Range
Default
d1-24
Inspection Operation Speed
0.00 to 100.00% <1>
50.00% <1>
<1> Setting ranges and defaults vary by the setting units determined by param eter o1-03. Refer to
Defaults and Setting Ranges by D isplay U nit
Selection (o1-03) on page 365
for details.
■ d1-25: Rescue Operation Speed
Determines the speed during Rescue Operation. Refer to
Rescue Operation on page 114
for details.
No.
Name
Setting Range
Default
d1-25
R escue Operation Speed
0.00 to 100.00% <1>
10.00% <1>
<1> Setting ranges and defaults vary by the setting units determined by param eter o1-03. Refer to
Defaults and Setting Ranges by D isplay U nit
Selection (o1-03) on page 365
for details.
■ d1-26: Leveling Speed
Sets the inspection speed when a multi-function input terminal is programmed for “Leveling speed” (H1-DD = 53).
No.
Name
Setting Range
Default
d1-26
Leveling Speed
0.00 to 100.00% <1>
8.00% <1>
<1> Setting ranges and defaults vary by the setting units determined by param eter o1-03. Refer to
Defaults and Setting Ranges by D isplay U nit
Selection (o1-03) on page 365
for details.
■ Motor Switch Selection
When an input terminal selects motor 2 (H 1-DD = 16), the drive will operate a second motor using V /f Control. The
drive cannot control motor 2 with OLV, CLV or CLV/PM.
The motor 2 speed reference in d1-27 can also be used to operate motor 1 using V /f Control. Refer to
Table 5.8
for
combinations of selecting the speed reference for motor 2 and the motor 1/2 selection switch. (H 1-DD = 53).
Table 5.8 Speed Reference for M otor 2, Controlling Motor 1 and 2
The value set to d1-27
Speed reference
Control mode
Accel/Decel ramp
S-character/ Jerk
Contactor/
Brake sequence
Purpose
0.00
speed reference set to
Motor 1
V /f with motor 1 <1>
C1-01 to C1-08
C2-01 to C2-05
Available
Hoist
not 0.00
d1-27
V /f with motor 2
C1-12/C1-13
N.A.
N.A.
N ot for hoist
<1> Enter the same values to the E3 and E4 param eters that are set for the E1 and E2 parameters.
YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual