5.7 H: Terminal Functions
Setting 8, 9: Baseblock command
When the drive receives a baseblock command, the output transistors stop switching, the motor coasts to stop, and a bb
alarm flashes on the digital operator to indicate baseblock.
Digital Input Function
Drive Operation
Input Open
Input Closed
Setting 8 (N .O .)
Baseblock (Interrupt output)
Normal operation
Setting 9 (N .C .)
Normal operation
Baseblock (Interrupt output)
W ARNING!
S ud de n M o v e m e n t Hazard. W hen u s in g a m e c h a n ic a l h o ld in g b ra k e w ith th e drive in a liftin g ap plicatio n, clo se the bra ke
w h en the drive o u tp u t is c u t o f f b y a b a s e b lo c k c o m m a n d trig g e re d b y o n e o f the in p u t term inals. F ailure to c o m p ly w ill re s u lt in a
s lip p in g lo a d from the m o to r s u d d e n ly c o a s tin g w hen the b a s e b lo c k c o m m a n d is e n te re d a n d m a y cau se seriou s in ju ry o r death.
Setting F: Not used (Through mode)
Select this setting when using the terminal in a pass-through mode. When set to F, an input does not trigger any function
in the drive. Setting F, however, still allows the input status to be read out by a PLC via a communication option or
MEMOBUS/Modbus communications.
Setting 14: Fault reset
When the drive detects a fault condition, the fault output contact closes, the drive output shuts off, and the motor coasts to
stop (specific stopping methods can be selected for some faults such as L1-04 for motor overheat). After removing the
Up/Down command, clear the fault either by pressing the RESET key on the digital operator or closing a digital input
configured as a Fault Reset (И1-ПП = 14).
N ote: Rem ove the U p/D ow n comm and prior to resetting a fault. Fault Reset comm ands are ignored w hile the U p/D own comm and is
present.
Setting 15, 17: Fast Stop (N.O., N.C.)
The Fast Stop function operates similar to an emergency stop input to the drive. If a Fast Stop command is input while
the drive is running, the drive decelerates to a stop in the deceleration time set to C1-09
(Refer to C1-09: Emergency
Stop Ramp on page 145).
The drive can only be restarted after bringing the drive to a complete stop, turning off the Fast
Stop input, and switching off the Up/Down command.
• To trigger the Fast Stop function with a N.O. switch, set И 1-П П = 15.
• To trigger the Fast Stop function with a N.C. switch, set И 1-П П = 17.
Figure 5.16
shows an operation example o f Emergency Stop.
Up/Down/Stop----------------------------------------------------------------
ON
ON
Fast Stop ■
H i-СП = 17
ON
ON
F ig u r e 5 .1 6 F a s t S to p S e q u e n c e
N O TICE:
R a p id d e c e le ra tio n c an trig g e r an ove rvo lta g e fault. W hen faulted, the d riv e o u tp u t shu ts off, a n d the m o to r coasts. To a v o id
th is u n c o n tro lle d m o to r state a n d to e n sure th a t the m o to r stop s q u ic k ly a n d safely, se t an a p p ro p ria te F a s t S top tim e to C1-09.
172