4.3 The Drive and Programming Modes
4.3
The Drive and Programming Modes
The drive has a Drive Mode to operate the motor and a Programming Mode to edit parameter settings.
Drive Mode:
In Drive Mode the user can operate the motor and observe U Monitor parameters. Parameter settings
cannot be edited or changed when in Drive Mode.
Programming Mode:
In Programming Mode the user can edit and verify parameter settings and perform Auto-Tuning.
The drive will not accept an Up/down command when the digital operator is in the Programming Mode unless parameter
b1-08 is set to 1 to allow an Up/down command.
Note: 1. I f b1-08 is set to 0, the drive will only accept an U p/D own comm and in Drive M ode. A fter editing param eters, the user m ust exit the
Program m ing Mode and enter D rive M ode before operating the motor.
2. Set b1-08 to 1 to allow the drive to run the motor while in Program m ing Mode.
♦ Navigating the Drive and Programming Modes
The drive is set to operate in Drive Mode when it is first powered up. Switch between display screens by using the
and
j
keys.
Mode
Contents
Operator Display
Description
P o w er U p
Speed Reference
(default)
- MODE - DRV Rdy
Speed Ref (OPR)
U1-01= 0.00%
U1-02= 0.00%
U1-03= 0.00A
FWD
RSEQ
LREF
This display screen allows the user to monitor and change the speed reference w hile the drive is running. R efer to
The D rive a n d Program m ing M odes on p a g e 8 2 .
N ote: The user can select the data displayed w hen the drive is first powered up with parameter o1-02.
D rive M ode
Monitor Display
- MODE - DRV Rdy
Monitor Menu
U1-01= 0.00%
U1-02= 0.00% RSEQ
U1-03= 0.00A I
lref
FWD
■
Lists the monitor parameters ( U D -П П parameters) available in the drive.
Press the Enter Key and then use the Up, D own, ESC, and Reset keys to navigate through the drive monitors.
Verify Menu
- MODE -
PRG
Modified Consts
Modified
X Parameters
l ! E I J FWD hTiWil
Lists all parameters that have been edited or changed from default settings.
C hanges: Verify M enu on p a g e 8 5 .
R efer to Verifying Param eter
a
T o
Program m in g
M ode
Setup Group
- MODE -
PRG
Quick Setting
E I U J FWD г и п д
A select list o f parameters necessary to get the drive operating quickly.
p a g e 8 6 .
R efer to U sing th e Setu p G rou p on
LI
| T
LI
Parameter Setting
Mode
- MODE -
PRG
Programming
H S U FWD ЦАТЛ
A llow s the user to access and edit all parameter settings.
R efe r to P aram eter Table on p a g e 3 2 4 .
Program m in g
M ode
Auto-Tuning Mode
- MODE -
PRG
Auto-Tuning
C AUTO ^
IHIELJ FWD ПАПД
в J| a
Motor parameters are calculated and set automatically.
R efer to A u to-T u n in g on p a g e 9 5 .
82