B.3 Parameter Table
■ b8: Energy Saving
Setting
Page
Default: 0
Min: 0
143
Max: 1
Default: 0.10
Min: 0.00
143
Max: 2.00
Default: 1.00
Min: 0.00
143
Max: 2.00
No.(Addr.)
b8-01
(1CCH)
Name
Description
Energy Saving Control Selection
;
c l v
;
0: Disabled
1: Enabled
b8-16
(1F8H)
Energy Saving Control Constant
(Ki)
CLV
■
CLV/PM
Enter the Energy Saving value (Ki) as specified on the motor name plate. (for IPM motors only)
b8-17
(1F9H)
Energy Saving Control Constant
(Kt)
CLV
■
CLV/PM
Enter the Energy Saving value (Kt) as specified on the motor name plate. (for IPM motors only)
♦ C: Tuning
C parameters are used to adjust the acceleration and deceleration ramps, jerk settings, slip compensation, torque
compensation, and carrier frequency selections.
■ C1: Acceleration and Deceleration Ramps
No.(Addr.)
Name
Description
Setting
Page
C1-01
(200H)
C1-02
(201H)
C1-03
(202H)
C1-04
(203H)
C1-05
(204H)
C1-06
(205H)
C1-07
(206H)
C1-08
(207H )
C1-09
(208H )
Acceleration Ramp 1
Sets the ramp to accelerate from 0 to maximum speed.
Deceleration Ramp 1
Sets the ramp to decelerate from maximum speed to 0.
Acceleration Ramp 2
Sets the ramp to accelerate from 0 to maximum speed.
Deceleration Ramp 2
Sets the ramp to decelerate from maximum speed to 0.
Acceleration Ramp 3 (Motor 2
A ccel Time 1)
Sets the ramp to accelerate from 0 to maximum speed.
Deceleration Ramp 3 (Motor 2
D ecel Time 1)
Sets the ramp to decelerate from maximum speed to 0.
Acceleration Ramp 4 (Motor 2
A ccel Time 2)
Sets the ramp to accelerate from 0 to maximum speed.
Deceleration Ramp 4 (Motor 2
D ecel Time 2)
Sets the ramp to decelerate from maximum speed to 0.
Emergency Stop Ramp
Sets the ramp for the Emergency Stop function.
Default: 1.50 s <6> <8>
Min: 0.00 s
Max: 600.00 s <6> <8>
144
144
144
144
144
144
144
145
C1-10
(209H )
A ccel/D ecel Setting Resolution
0: 0.01 s unit
1: 0.1 s unit
Default: 0
Min: 0
Max: 1
C1-11
(20A H )
A ccel/D ecel Switching Speed
Sets the speed to switch between accel/decel ramp settings.
Default: 0.0%
Min: 0.0%
Max: 100.0%
145
C1-12
(246H )
Motor 2 Acceleration Time
CLV
■
CLV/PM
Sets the acceleration tim e for motor 2.
N o t e :
Parameter C1-12 determines the acceleration tim e for motor 2 as long as d1-27 is not set
Default: 1.0 s
Min: 0.0 s
Max: 600.0 s
1 46
C1-13
Motor 2 Acceleration Time
CLV
■
CLV/PM
Sets the deceleration time for motor 2.
Default: 1.0 s
Min: 0.0 s
Max: 600.0 s
1 46
C1-15
(260H )
Inspection Deceleration Ramp
Sets the deceleration ramp used for inspection run.
Default: 0.00 s <6> <8>
Min: 0.00 s
Max: 2.00 s <6> <8>
<6> Setting ranges and defaults vary by the setting units determined by param eter o1-03.
Refer to
Defaults a n d S etting Ranges by D isplay U n it Selection (o1-03) on page 365
<8> Setting range value is dependent on param eter C1-10, Accel/Decel Setting Resolution. W hen C1-10 = 0 (units o f 0.01 seconds), the setting
range becomes 0.00 to 600.00 seconds.
CLV/PM
V/f
V/f
144
1 46
V/f
V/f
1 46
326
YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual