B.3 Parameter Table
■ H3: Multi-Function Analog Inputs
No.(Addr.)
Name
Description
Setting
Page
H3-01
(410H)
Terminal A1 Signal L evel
Selection
0: 0 to 10 V
1: - 1 0 to 10 V
Default: 0
Min: 0
Max: 1
H3-02
(434H)
Terminal A1 Function Selection
Sets the function o f terminal A 1 .
Default: 0
Min: 0
Max: 1F
183
H3-03
(411H)
Terminal A1 Gain Setting
Sets the level o f the input value selected in H3-02 when 10 V is input at terminal A1.
Default: 100.0%
Min: -999.9%
Max: 999.9%
H 3-04
(412H)
Terminal A1 Bias Setting
Sets the level o f the input value selected in H3-02 when 0 V is input at terminal A1.
Default: 0.0%
Min: -999.9%
Max: 999.9%
H3-09
(417H)
Terminal A 2 Signal L evel
Selection
0: 0 to 10 V
1: - 1 0 to 10 V
Default: 0
Min: 0
Max: 0
184
H3-10
(418H)
Terminal A 2 Function Selection
Sets the function o f terminal A2.
Default: 0
Min: 0
Max: 1F
185
H3-11
(419H)
Terminal A 2 Gain Setting
Sets the level o f the input value selected in H3-10 when 10 V is input at terminal A2.
Default: 100.0%
Min: -999.9%
Max: 999.9%
185
H3-12
(41AH)
Terminal A 2 Bias Setting
Sets the level o f the input value selected in H3-10 when 0 V is input at terminal A2.
Default: 0.0%
Min: -999.9%
Max: 999.9%
185
H3-13
(41B H )
Analog Input Filter Time Constant
Sets a primary delay filter tim e constant for terminals A1 and A2. U sed for noise filtering.
Default: 0.03 s
Min: 0.00 s
Max: 2.00 s
H3-16
(2F0H)
Offset for Terminal A1
Applies an offset to analog input A1. Can be used for zero adjustment o f the analog input.
Default: 0
Min: -500
Max: 500
185
H 3-17
(2F1H)
Offset for Terminal A2
Applies an offset to analog input A2. Can be used for zero adjustment o f the analog input.
Default: 0
Min: -500
Max: 500
185
183
184
184
185
H3 Multi-Function Analog Input Settings
Н 3-П П
Setting
Function
Description
Page
Speed Reference Bias
(value added to input signal when multiple
analog terminals supply the speed reference)
10 V = E 1-04 (maximum output frequency)
Auxiliary Speed Reference 1 (used as a second
speed reference)
186
10 V = E 1-04 (maximum output frequency)
Auxiliary Speed Reference 2 (used as third
speed reference)
186
10 V = E 1-04 (maximum output frequency)
14
Torque Compensation (load cell input)
CLV
И
CLV/PM
186
10 V = Motor rated torque
N ot used (Through M ode)
Sets this value when using the terminal in the pass-through mode.
0
186
2
3
V/f
1F
186
■ H4: Analog Outputs
No.(Addr.)
Name
|
Description
Setting
Page
H4-01
(41D H )
Terminal FM Monitor Selection
I
S
S
f
elects the data
et the desired m
or U1-03.
o be output through m ulti-function analog output terminal FM.
lonitor parameter to the digits available in U D -П П . For example, enter “ 103”
Default: 102
Min: 000
Max: 999
186
H4-02
(41EH)
Terminal FM Gain
I
Sets the signal le
I H I I I I | I I I I I I I 1
v e l at terminal FM that is equal to 100% o f the selected monitor value.
Default: 100.0%
Min: -999.9%
Max: 999.9%
186
H4-03
(41FH)
Terminal FM Bias
I
Sets the signal le
IIH IIIIH IIIIIIIIH II 1
v el at terminal FM that is equal to 0% o f the selected monitor value.
Default: 0.0%
Min: -999.9%
Max: 999.9%
186
340