4.3 The Drive and Programming Modes
Mode
Contents
Operator Display
Description
D rive M od e
Speed Reference
- MODE -
DRV Rdy
S p e e d R ef (OPR)
U 1-01= 0.00%
U1-02= 0.00% RSEQ
U1-03= 0.00A
l r e p
p w d
Returns to the speed reference display screen.
■ Drive Mode Details
The following actions are possible in the Drive Mode:
• Run and stop the drive
• Monitor the operation status o f the drive (speed reference, output speed, output current, output voltage, etc.)
• View information on an alarm
• View a history of alarms that have occurred
Figure 4.6
illustrates how to change the speed reference from 0.00% to 10.00% while in the Drive Mode. This example
assumes the reference source is assigned to the digital operator (b1-02 = 0) and d1-01 is set to 0 or 3.
S p e e d re feren ce
d isp lay at p o w er up
- MODE - DRV Rdy
Speed Ref (OPR)
U1-01 = 0.00%
U1-02= 0.00% IRSEQI
U1-03= 0.00A
I
l r e p
I
■
pWD
\
-MONITR- DRV Rdy
Spd Ref 1(d1-01)
U1-01 = 000.00%
(0.00-100.00)
____“ 0.00%"____
и
p w d
ШШ
le ft
rig h t
□
И
P r e s s u n til t h e fr e q u e n c y
re fe r e n c e c h a n g e s t o 0 1 0 .0 0 %
p1
-MONITR- DRV Rdy
Spd Ref 1(d1-01)
U1-01 = 010.00%
(0.00-100.00)
____“ 0.00%"___
■
Л
p w d
Е Э
-MONITR- DRV Rdy
Spd Ref 1(d1-01)
U1-01= 01000%
Entry Accepted
(0.00-100.00%)
Ш Я
p w d
- MODE - DRV Rdy
Speed Ref (OPR)
U1-01= 10.00%
U1-02= 0.00% I
r s
E
q
I
U1-03= 0.00A I
l
R
e p
I
pWD
F ig u r e 4 .6 S e tt in g t h e S p e e d R e f e r e n c e w h ile in t h e D riv e M o d e
Note: The drive will not accept a change to the speed reference until the EN TER key is pressed after the speed reference is entered.
This feature prevents accidental setting o f the speed reference. To have the drive accept changes to the speed reference as soon as
changes are made w ithout requiring the EN TER key, set o2-05 to 1.
■ Programming Mode Details
The following actions are possible in the Programming Mode:
•
Parameter Setting Mode:
Access and edit all parameter settings.
•
Verify Menu:
Check a list o f parameters that have been changed from their original default values.
•
Setup Group:
Access a list o f commonly used parameters to simplify setup (refer to
Simplified Setup Using the Setup
Group on page 86)
•
Auto-Tuning Mode:
Automatically calculate and set motor parameters to optimize drive performance.
YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual
83