5.11 S: Elevator Parameters
■ S3-04: Position Lock Bandwidth
Determines the bandwidth around the locked position to enable a digital output set for И 2-П П = 33 (within position lock
bandwidth). The output will be triggered when the car moves from the Position Lock start point to plus or minus the
number o f pulses set to S3-04.
No.
Parameter Name
Setting Range
Default
S3-04
Position Lock Bandwidth
0 to 16383
10
■ S3-10: Starting Torque Compensation Increase Time
Sets a time constant for the torque reference to reach 300%. Enabled by setting an analog input terminal for torque
compensation (H3-DD = 14).
No.
Parameter Name
Setting Range
Default
S3-10
Starting Torque Compensation Increase Time
0 to 5000 ms
500 ms
■ S3-12: Starting Torque Compensation Bias in Down Direction
Adds a bias to torque compensation in Down direction.
Refer to
Adjusting the Torque Compensation at Start on page 112
for details.
No.
Parameter Name
Setting Range
Default
S3-12
Starting Torque Compensation Bias in D own Direction
-4 0 .0 to 40.0%
0.00%
■ S3-14: Torque Compensation Fade Out Speed
Sets the speed level for torque compensation to fade out during the time determined by S3-15. Set as a percentage o f the
maximum output frequency (E1-04). A setting o f 0.0% disables this function.
No.
Parameter Name
Setting Range
Default
S3-14
Torque Compensation Fade Out Speed
0.0 to 100.0%
0.0%
■ S3-15: Torque Compensation Fade Out Time
Sets the time for torque compensation to fade out when motor speed reaches the level set in S3-14.
No.
Parameter Name
Setting Range
Default
S3-15
Torque Compensation Fade Out Time
0 to 5000 ms
1000 ms
■ S3-16: Torque Limit Reduction Time
After Position Lock at stop, S3-16 determines the length o f time to reduce the torque limit rate = Тог^ие
No.
Parameter Name
Setting Range
Default
S3-16
Torque Limit Reduction Time
0 to 10000 ms
100 ms
■ S3-20: Dwell 2 Speed Reference
Sets the speed reference for the Dwell 2 function.
Note: Setting this param eter to 0.00 disables the D well 2 function.
No.
Parameter Name
Setting Range
Default
S3-20
D w ell 2 Speed Reference
0.00 to 100.00
0.00%
Run Command
ON
YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual
221
P
a
ra
m
e
te
r
D
e
ta
il
s