B.3 Parameter Table
♦ d: Speed References
Speed Reference parameters are used to set the various speed reference values during operation.
■ d1: Speed Reference
No.(Addr.)
Name
d1-01
(280H)
Speed Reference 1
d1-02
(281H)
Speed Reference 2
d1-03
(282H)
Speed Reference 3
d1-04
(283H)
Speed Reference 4
d1-05
(284H )
Speed Reference 5
d1-06
(285H )
Speed Reference 6
d1-07
(286H )
Speed Reference 7
d1-08
(287H )
Speed Reference 8
d1-18
(2C0H)
Speed Reference Selection Mode
d1-19
(2C1H)
Nom inal Speed
d1-20
(2C2H)
Intermediate Speed 1
d1-21
(2C3H)
Intermediate Speed 2
d1-22
(2C4H)
Intermediate Speed 3
d1-23
(2C5H)
R eleveling Speed
d1-24
(2C6H)
Inspection Operation Speed
d1-25
(2C7H)
R escue Operation Speed
d1-26
(2C8H)
Leveling Speed
d1-27
(2C9H)
Motor 2 Speed Reference
Description
Setting
Page
Sets the Speed reference for the drive w hen d1-18 is set to 0 or 3. Setting units are determined
by parameter o1-03.
Default: 0.00% <6>
Min: 0.00%
Max: 100.00% <6>
154
154
154
154
Sets the m ode o f speed reference selection by digital inputs.
0: U se m ulti-speed references (d1-01 to d1-08)
1: High speed reference has priority (d1-19 to d1 -23, d1-26)
2: Leveling speed reference has priority (d1-19 to d1-23, d1-26)
3: U se multi-speed references d1-02 to d1-08, no speed selection stops the drive. Drive w ill stop
when all input terminals programmed for speed references (H 1 -D D = 3, 4, 5) are open.
Default: 1
Min: 0
Max: 3
Sets the nominal speed reference when d1-18 = 1 or 2.
Default: 100.00% <6>
Min: 0.00%
Max: 100.00% <6>
154
Sets intermediate speed reference 1 when d1-18 = 1 or 2.
Default: 0.00% <6>
Min: 0.00%
Max: 100.00% <6>
155
Sets intermediate speed reference 2 when d1-18 = 1 or 2.
Default: 0.00% <6>
Min: 0.00%
Max: 100.00% <6>
Sets intermediate speed reference 3 when d1-18 = 1 or 3.
Default: 0.00% <6>
Min: 0.00%
Max: 100.00% <6>
155
Sets speed reference for releveling when d1-18 = 1 or 2.
Default: 0.00% <6>
Min: 0.00%
Max: 100.00% <6>
155
Sets speed reference when inspection operation is enabled.
Default: 50.00% <6>
Min: 0.00%
Max: 100.00% <6>
Sets the speed reference during inspection operation.
Default: 10.00% <6>
Min: 0.00%
Max: 100.00% <6>
Sets leveling speed reference when d1-18 = 1 or 2.
Default: 8.00% <6>
Min: 0.00%
Max: 100.00% <6>
155
С
V /f
■
O LV
■
CLV
■
CLV/PM
Sets the speed reference for motor 2.
N o t e :
1. If set to 0.00, the drive w ill control motor 1 instead.
2. W hen using motor 2, be sure that the accel/decel times are set in parameters C1-12
and C1-13.
Default: 0.00 Hz
Min: 0.00 Hz
Max: 120.00 Hz
156
YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual
329
154
154
154