5.2 b: Application
♦ b4: Delay Timers
The timer function is independent of drive operation and can delay the switching o f a digital output triggered by a digital
input signal and help eliminate chattering switch noise from sensors. An on-delay and off-delay can be set separately.
To enable the timer function, set a multi-function input to Timer input (H1-DD=18) and set a multi-function output to
Timer output (H2-DD=12). Only one timer can be used.
■ b4-01, b4-02: Timer Function On-Delay, Off-Delay Time
b4-01 sets the on-delay time for switching the timer output. b4-02 sets the off-delay time for switching the timer output.
No.
Name
Setting Range
Default
b4-01
Timer Function On-Delay Time
0.0 to 3000.0 s
0.0 s
b4-02
Timer Function Off-Delay Time
0.0 to 3000.0 s
0.0 s
■ Timer Function Operation
The timer function switches on when the timer function input closes for longer than the value set to b4-01. The timer
function switches off when the timer function input is open for longer than the value set to b4-02.
Figure 5.2
illustrates
the timer function operation:
Multi-function Contact
Input: Timer Function
Multi-function Contact
Output: Timer Function 1
O N
____
ПИП
O N
1 1 1 1 1 1
O N
O N
M
►
■4
►
1
^ —
►
On (Closed)
Off (Open)
On (Closed)
Off (Open)
b 4 -0 2
b4-01
F ig u r e 5.2 T im e r O p e r a tio n
♦ b6: Dwell Function
The Dwell function temporarily holds the frequency reference at a predefined value for a set time then continues
accelerating or decelerating.
Figure 5.3
shows how the Dwell function works.
N ote: Set the stopping method to "Ramp to Stop" (b1-03 = 0) to use the Dwell function.
F ig u r e 5 .3 D w ell F u n c tio n a t S t a r t a n d S to p
■ b6-01, b6-02: Dwell Speed, Dwell Time at Start
Parameter b6-01 determines the speed that is held or the time set in b6-02 during acceleration.
No.
Name
Setting Range
Default
b6-01
D w ell Speed at Start
0.0 to 100.0% <1>
0.0%
b6-02
D w ell Time at Start
0.0 to 10.0 s
0.0 s
<1> A setting o f 100% is equal to the maxim um speed.
■ b6-03, b6-04: Dwell Speed, Dwell Time at Stop
Parameter b6-03 determines the speed that is held for the time set in b6-04 during deceleration.
No.
Name
Setting Range
Default
b6-03
D w ell Speed at Stop
0.0 to 100.0% <1>
0.0%
b6-04
D w ell Time at Stop
0.0 to 10.0 s
0.0 s
<1> A setting o f 100% is equal to the maxim um speed.
142