A.1 Three-Phase 200 V Class Drives
A.1 Three-Phase 200 V Class Drives
Table A.1 Power Ratings (Three-Phase 200 V Class)
Item
Specification
CIMR-LC2A
0018
0025
0033
0047
0060
0075
0085
0115
0145
0180
0215
0283
0346
0415
M a x i m u m A p p l i c a b l e M o t o r C a p a c i t y
( k W )
<1>
4.0
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
I n p u t
I n p u t C u r r e n t ( A )
<2>
18.9
28
37
52
68
80
82
111
136
164
200
271
324
394
R a t e d V o l t a g e
R a t e d F r e q u e n c y
Three-phase 200 to 240 V 50/60 Hz
A l l o w a b l e V o l t a g e F l u c t u a t i o n
-15 to 10%
A l l o w a b l e F r e q u e n c y F l u c t u a t i o n
±5%
I n p u t P o w e r ( k V A )
9.5
14
18
27
36
44
37
51
62
75
91
124
148
180
O u t p u t
R a t e d O u t p u t C a p a c i t y ( k V A )
<3>
6.7
9.5
12.6
17.9
23
29
32
44
55
69
82
108
132
158
R a t e d O u t p u t C u r r e n t ( A )
17.5
<4>
25
<4>
33
<4>
47
<4>
60
<4>
75
<4>
85
<4>
115
<4>
145
<5>
180
<5>
215
<5>
283
<5>
346
<6>
415
<6>
O v e r l o a d T o l e r a n c e
150% o f rated output current for 60 s
C a r r i e r F r e q u e n c y
User adjustable between 2 and 15 kHz
User adjustable betw een 2 and
10 kHz
M a x i m u m O u t p u t V o l t a g e ( V )
Three-phase 200 to 240 V (proportional to input voltage)
M a x i m u m o u t p u t s p e e d ( H z )
120 H z (user-set)
<1> The m otor capacity (kW) refers to a Yaskawa 4-pole motor. The rated output current o f the drive output amps should be equal to or greater than
the m otor rated current. Select the appropriate capacity drive i f operating the m otor continuously above m otor nam eplate current.
<2> Assum es operation at the rated output current. Input current rating varies depending on the power supply transform er, input reactor, wiring
connections, and power supply impedance.
<3> Rated m otor capacity is calculated w ith a rated output voltage o f 220 V.
<4> Carrier frequency can be set up to 8 kHz w hile keeping this current rating. H igher carrier frequency settings require derating.
<5> Carrier frequency can be set up to 5 kHz w hile keeping this current rating. H igher carrier frequency settings require derating.
<6> Carrier frequency can be set up to 2 kHz w hile keeping this current rating. H igher carrier frequency settings require derating.
314