B.3 Parameter Table
No. (Addr.)
Name
Description
Setting
Page
L4-06
(4C2H)
Speed Reference at Reference Loss
S
r
ets the percenta
eference is lost.
ge o f the speed reference that the drive should run with when the speed
Default: 80%
Min: 0.0%
Max: 100.0%
194
L4-13
(4F6H)
Door Zone Level
1
S
s
ets the door zor
peed falls below
Н
Н
^ Н
Н
Ш
Н
1
ie speed level. The "door zone" m ulti-function digital output is closed when the
this level.
Default: 0.0%
Min: 0.0%
Max: 100.0%
194
■ L5: Automatic Fault Reset
No. (Addr.)
Name
|
Description
Setting
Page
L5-01
(49EH)
Number o f Auto Reset Attempts
i
S
o
ets the number
C, ov, rr, oH1,
o f times the drive may attempt to reset after the follow ing faults occur: GF, LF,
oL1, oL2, oL3, oL4, UL3, UL4.
Default: 0
Min: 0
Max: 10
195
L 5-02
(49FH)
Fault Output Operation during
Auto Reset
i
0
1
: Fault output n
: Fault output a
1
ot active.
ctive during reset attempt.
Default: 0
Min: 0
Max: 1
195
L 5-06
(522H)
Undervoltage Fault Reset
Selection
i
0
1
: Same as L5-0
: A lw ays autom
i
1 condition
atically reset UV1
Default: 0
Min: 0
Max: 1
195
■ L6: Torque Detection
No. (Addr.)
Name
Description
Setting
Page
L6-01
(4A1H)
Torque Detection Selection 1
Disabled
oL3 detection only active during speed agree, operation continues after detection
oL3 detection always active during run, operation continues after detection
oL3 detection only active during speed agree, output shuts down on an oL3 fault
oL3 detection always active during run, output shuts down on an oL3 fault
UL3 detection only active during speed agree, operation continues after detection
UL3 detection always active during run, operation continues after detection
UL3 detection only active during speed agree, output shuts down on an oL3 fault
UL3 detection always active during run, output shuts down on an oL3 fault
Default: 0
Min: 0
Max: 8
L 6-02
(4A2H)
Torque Detection L evel 1
Sets the overtorque and undertorque detection level.
Default: 150%
Min: 0%
Max: 300%
L6-03
(4A3H)
Torque Detection Time 1
Sets the tim e an overtorque or undertorque condition must exist to trigger torque detection 1.
Default: 0.1 s
Min: 0.0 s
Max: 10.0 s
1 97
L 6-04
(4A4H)
Torque Detection Selection 2
Disabled
oL4 detection only active during speed agree, operation continues after detection
oL4 detection always active during run, operation continues after detection
oL4 detection only active during speed agree, output shuts down on an oL4 fault
oL4 detection always active during run, output shuts down on an oL4 fault
U L 4 detection only active during speed agree, operation continues after detection
U L 4 detection always active during run, operation continues after detection
U L 4 detection only active during speed agree, output shuts down on an oL4 fault
U L 4 detection always active during run, output shuts down on an oL4 fault
Default: 0
Min: 0
Max: 8
196
L6-05
(4A5H)
Torque Detection L evel 2
Sets the overtorque and undertorque detection level.
Default: 150%
Min: 0%
Max: 300%
1 97
L 6-06
(4A6H)
Torque Detection Time 2
Sets the tim e an overtorque or undertorque condition must exist to trigger torque detection 2.
Default: 0.1 s
Min: 0.0 s
Max: 10.0 s
1 97
196
1 97
IE
YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual