B.3 Parameter Table
H1 Multi-Function Digital Input Settings
И 1-П П
Setting
Function
Description
Page
20 to 2F
External Fault
20: N.O., A lw ays detected, ramp to stop
21: N .C., A lw ays detected, ramp to stop
22: N.O., During run, ramp to stop
23: N .C., During run, ramp to stop
24: N.O., A lw ays detected, coast to stop
25: N .C., A lw ays detected, coast to stop
26: N.O., During run, coast to stop
27: N .C., During run, coast to stop
28: N.O., A lw ays detected, Emergency Stop
29: N .C., A lw ays detected, Emergency Stop
2A: N.O., During run, Emergency Stop
2B: N .C., During run, Emergency Stop
2C: N.O., A lw ays detected, alarm only (continue running)
2D: N .C., A lw ays detected, alarm only (continue running)
2E: N.O., During run, alarm only (continue running)
2F: N .C., During run, alarm only (continue running)
173
Nom inal Speed
Closed: Activates the nominal speed (d1-19).
51
Intermediate Speed
Closed: Activates the Intermediate Speed (d1-20).
174
52
R eleveling Speed
Closed: Activates the Releveling Speed (d1-23).
174
Leveling Speed
Closed: Activates the Leveling Speed (d1-26).
54
Inspection Operation
Closed: Activates Inspection operation using the speed set in d1-24.
174
R escue Operation
Closed: Activates rescue operation.
56
Motor Contactor Feedback
U sed for motor contactor supervision and fault detection.
174
57
High Speed Limit (Up)
Closed: U ses the leveling speed as the maximum speed when going up.
174
58
High Speed Limit (D own)
Closed: U ses the leveling speed as the m axim um speed w hen going down.
174
Floor Sensor
CLV
■
CLV/PM
Closed: Initiate D irect Landing (S5-10 = 1)
67
Communications Test Mode
175
Tests the M EM OBUS/M odbus R S-485/422 interface. Displays “PASS” i f the test com pletes successfully.
Brake Feedback
U sed for brake supervision and detection o f incorrect operation.
53
55
V/f
5C
79
■ H2: Multi-Function Digital Outputs
No.(Addr.)
Name
H2-01
(40BH)
Terminals M 1-M 2 Function
Selection (relay)
H 2-02
(40CH)
Terminals M 3-M 4 Function
Selection (relay)
H2-03
(40DH)
Terminals M 5-M 6 Function
Selection (relay)
H 2-04
(40EH)
Terminal P1-C1 Function
Selection (photocoupler)
H2-05
(40FH)
Terminal P2-C2 Function
Selection (photocoupler)
Description
Setting
Page
Default: 50
Min: 0
175
Max: 161
Default: 51
Min: 0
175
Max: 161
Default: 6
Min: 0
175
Max: 161
Default: 37
Min: 0
175
Max: 161
Default: F
Min: 0
175
Max: 161
Refer to H 2 M ulti-F unction D ig ita l O u tp u t S ettin g s on p a g e 3 3 8 for a description o f setting
values.
YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual
337
P
a
ra
m
e
te
r
L
is
t