Input Voltage

18V-24V DC (24V DC is recommended)

Input Current

100mA

I/O Connecons

C-Bus

4 X screw terminals

Output

1 X 5A relay channel (screw terminal)

Input

1 X digital dry contact input (screw terminal)

1 X 4-wire wiegand input 

Pr

od

uc

t

 S

pe

ci

fic

a

on

 

(CL-AB-RF-W)

Wiegand Converter

C-Bus

I/O Connecons

Wieg

and Connecons

1. VCC
2. GND
3. A (Data+)
4. B (Data-)

5. Contact input

6. Normal open contact

7. COM

8. VCC (12V DC)

9. GND

10. Data 1 (Wiegand)

11. Data 0 (Wiegand)

No

C

In

B

A

-

+

3

4

2

1

6

5

7

Power In: 18-24V DC

100mA max

CL-AB-RF-W

Wiegand Converter

-

+

D0

D1

8

9

10

11

1. Power LED
2. Status LED
3. Output LED
4. Input LED
5. Address selector switch

0

0

0

2

9

5

0

0

0

0

F

A

1

4

E

7

Out

In

1

2

3

4

5

ON

5

1
2

3
4

INSTALLATION GUIDE 

 version 1.0.1

3

4

1

2

Before wiring the device, always unplug the main power.

In case of using capaciv e or inducv e loads, permissible current is less than normal mode (resisv e load) 

depending on load condion.

Use the following wiring diagram when input voltage of the Wiegand Reader is equal to 12V DC and 

input current is lower than or equal to 100mA.

No

C

In

B

A

-

+

To Next Module

From Previous

 Module

Power In: 18-24V DC

100mA max

CL-AB-RF-W

Wiegand Converter

-

+

D0

D1

MODE

Circut

Breaker

MODE

Circut

Breaker

MODE

Circut

Breaker

MODE

Circut

Breaker

MODE

Circut

Breaker

MODE

Circut

Breaker

MODE

Circut

Breaker

MODE

Circut

Breaker

N

L

Magnec

 Door Lock

12V / 100mA

GND

In