background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

EtherNet/IP Master/ CAN

 

 

Document code: MN67645_ENG     Revision 1.000   Page 1 of 27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual 

Revision 1.000 
English

 

 

EtherNet/IP Master / CAN - Converter

  

(Order Code:  HD67645-A1 ) 

 

For Website information:  

www.adfweb.com?Product=HD67645

    

 

For Price information: 

www.adfweb.com?Price=HD67645-A1

 

 
 

Benefits and Main Features: 

 

Very easy to configure 

 

Triple Electrical isolation 

 

Temperature range: -40°C/+85°C (-40°F/+185°F) 

 

For other EtherNet/IP Master products see also the following link: 

 

Converter EtherNet/IP Master to  

www.adfweb.com?Product=HD67B38

         

(OPC UA Server)

 

www.adfweb.com?Product=HD67D24

         

(LoRaWAN)

 

www.adfweb.com?Product=HD67E26

          

(EtherCAT)

 

www.adfweb.com?Product=HD67158

          

(SNMP Agent)

 

www.adfweb.com?Product=HD67643

          

(PROFIBUS Slave)

 

www.adfweb.com?Product=HD67645

         

(CAN)

 

www.adfweb.com?Product=HD67646

          

(CANopen)

 

www.adfweb.com?Product=HD67647

         

(DeviceNet Slave)

 

www.adfweb.com?Product=HD67661

         

(PROFINET)

 

www.adfweb.com?Product=HD67665

         

(Modbus TCP Slave)

 

www.adfweb.com?Product=HD67667

        

(Serial)

 

www.adfweb.com?Product=HD67668

         

(Ethernet)

 

www.adfweb.com?Product=HD67669

         

(Modbus Slave)

 

www.adfweb.com?Product=HD67689

          

(BACnet Slave)

 

www.adfweb.com?Product=HD67743

         

(IEC 61850 Server)

 

www.adfweb.com?Product=HD67806

         

(KNX)

 

www.adfweb.com?Product=HD67955

         

(MQTT) 

www.adfweb.com?Product=HD67973

         

(IO-Link Slave) 

 
 

User Manual   

 

Summary of Contents for HD67316-U-D1

Page 1: ...dfweb com Product HD67B38 OPC UA Server www adfweb com Product HD67D24 LoRaWAN www adfweb com Product HD67E26 EtherCAT www adfweb com Product HD67158 SNMP Agent www adfweb com Product HD67643 PROFIBUS Slave www adfweb com Product HD67645 CAN www adfweb com Product HD67646 CANopen www adfweb com Product HD67647 DeviceNet Slave www adfweb com Product HD67661 PROFINET www adfweb com Product HD67665 M...

Page 2: ...ECHNICAL SUPPORT 27 RETURN POLICY 27 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each page of this document With this Document Code go to web page www a...

Page 3: ...device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of this equipment and who have appropriate qualifications for their job RESIDUAL RISKS The device is state of the art and is safe The instruments can represent a potential hazard if they are inappro...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherNet IP Master CAN Document code MN67645_ENG Revision 1 000 Page 4 of 27 EXAMPLE OF CONNECTION ...

Page 5: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherNet IP Master CAN Document code MN67645_ENG Revision 1 000 Page 5 of 27 CONNECTION SCHEME Figure 1 Connection scheme for HD67645 A1 ...

Page 6: ... Supply Two directional information between EtherNet IP bus and CAN bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor SW67645 software on your PC in order to perform the following Define the parameters of EtherNet IP line Define the parameters of CAN line Define the list of EtherNet IP sl...

Page 7: ...7645_ENG Revision 1 000 Page 7 of 27 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at 24V DC Device Consumption W VA HD67645 A1 3 5 HD67645 A1 Caution Do not reverse the polarity power ...

Page 8: ...n the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used for uploading the Project and or Firmware For the operations to follow for the updating see UPDATE DEVICE section According to the functioning mode the LEDs will have specific functions see LEDS secti...

Page 9: ...nks when a CAN message is received Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 Device State green Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 4 Ethernet comm green It blinks when EtherNet IP communication is running Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 5 Ethernet1 link green ON Ethernet cable c...

Page 10: ...AN For terminating the CAN line with a 120Ω resistor it is necessary that the Dip1 of Dip Switch C is at ON position Cable characteristics DC parameter Impedance 70 Ohm m AC parameters Impedance 120 Ohm m Delay 5 ns m Length Baud Rate bps Length MAX m 10 K 5000 20 K 2500 50 K 1000 100 K 650 125 K 500 250 K 250 500 K 100 800 K 50 1000 K 25 ...

Page 11: ...using Connector3 and Connector4 of the HD67645 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mbps To connect the device to an Hub Switch is recommended the use of a straight cable to connect the device to a PC PLC other is recommended the use of a cross cable ...

Page 12: ... runs with Windows called SW67645 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on our web site The software works with MSWindows XP Vista Seven 8 10 32 64bit When launching the SW67645 the window below appears Fig 2 Note It is necessary to have installed Net Framework 4 Figure 2 M...

Page 13: ...figuration A device s configuration can also be imported or exported To clone the configurations of a programmable EtherNet IP Master CAN Converter in order to configure another device in the same manner it is necessary to maintain the folder and all its contents To clone a project in order to obtain a different version of the project it is sufficient to duplicate the project folder with another n...

Page 14: ...the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to check if there are some updatings of the software compositor in ADFweb com website Checking the option Check Software Update at Start of Program the SW67645 checks automatically if there are updatin...

Page 15: ...therNet IP Master CAN Document code MN67645_ENG Revision 1 000 Page 15 of 27 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside the tables contained in the different sections of the software ...

Page 16: ...In the field Baudrate the baudrate of the CAN line is defined The means of the fields for EtherNet IP Master are In the fields IP ADDRESS the IP address for EtherNet IP side of the converter is defined In the fields SUBNET Mask the SubNet Mask for EtherNet IP side of the converter is defined In the fields GATEWAY the default gateway of the net is defined This feature can be enabled or disabled pre...

Page 17: ...fined In the field Start Output the starting Output byte of the EtherNet IP Slave to write from CAN side is defined In the field Num Output the number of consecutive Output byte to write from CAN side is defined In the field Time Poll the polling time in ms is defined In the field Instance T O the instance of the assembly for the Target to Originator data direction is defined In the field Conn Poi...

Page 18: ... the field Dimension the number of byte of the COB from 1 to 8 is defined The field TimeOut is used for put at zero the data into EtherNet IP array if the CAN frame arrives with a frequency less than the time expressed in the field If the value in the field is 0 it means that you don t want to use this feature In the field Byte1 insert the byte of the EtherNet IP array where saving 1st byte of the...

Page 19: ...ield Byte6 insert the byte of the EtherNet IP array where saving 6th byte of the CAN message In the field Byte7 insert the byte of the EtherNet IP array where saving 7th byte of the CAN message In the field Byte8 insert the byte of the EtherNet IP array where saving 8th byte of the CAN message In the field Mnemonic a brief description is defined ...

Page 20: ...r 2 0B 29 bits In the field Dimension the number of byte of the COB from 1 to 8 is defined If the field OnChange is checked the frame is sent when the data from EtherNet IP change If the field OnCMD is checked the frame is sent when a EtherNet IP message is received If the field OnTimer is checked the frame is sent cyclically with the delay defined in the field Time expressed in ms In the field By...

Page 21: ...taking 5th byte of the CAN message In the field Byte6 insert the byte of the EtherNet IP array where taking 6th byte of the CAN message In the field Byte7 insert the byte of the EtherNet IP array where taking 7th byte of the CAN message In the field Byte8 insert the byte of the EtherNet IP array where taking 8th byte of the CAN message In the field Mnemonic it is possible to insert a brief descrip...

Page 22: ...rnet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 of Dip Switch A in OFF position Turn ON the device If you know the actual IP address of the device you have to use this procedure Turn ON the Device with the Ethernet cable inserted Insert the actual I...

Page 23: ... program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to program more than one device using the UDP Update you have to cancel the ARP table every time you connect a new device on Ethernet For do this you have to launch the Command Prompt and write the command arp d...

Page 24: ...trial Electronic Devices ADFweb com S r l User Manual EtherNet IP Master CAN Document code MN67645_ENG Revision 1 000 Page 24 of 27 MECHANICAL DIMENSIONS Figure 9 Mechanical dimensions scheme for HD67645 A1 ...

Page 25: ...id combination of the following HD67645 A 1 Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67645 EtherNet IP Master CAN Converter Order Code HD67645 A1 EtherNet IP Master CAN Converter ACCESSORIES Order Code AC34011 35mm Rail DIN Power Supply 220 240V AC 50 60Hz 12 V DC Order Code AC34012 35mm Rail DIN Power Supply 220 240V AC 50 60Hz 24 V...

Page 26: ...tion systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycling of electrical and electronic equipment If the product is disposed correctly you will help prevent potential negative environmental factors and impact of human health which could otherwise be ca...

Page 27: ...do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twelve months it will be repaired or exch...

Reviews: