background image

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Node-1                                                  V1

 

Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands 

Ordercode: 50802 

MANUAL 

ENGLISH 

Summary of Contents for Node-1

Page 1: ...Node 1 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 50802 MANUAL ENGLISH ...

Page 2: ...Determinations 3 Return Procedure 4 Claims 4 Description of the device 5 Frontside 5 Backside 5 Installation 6 Set Up and Operation 6 Start up 6 Connections 7 Data Cabling 9 Maintenance 9 Troubleshooting 9 No Light 9 No Response to DMX 10 Product Specifications 11 Dimensions 11 Notes 12 ...

Page 3: ...ncludes Showtec Node 1 DMX ArtNet 2 way converter Cat cable Power adapter 5V 500mA User manual Safety Instructions Every person involved with the installation operation and maintenance of this device has to be qualified follow the instructions of this manual Before the initial start up please make sure that there is no damage caused by transportation Should there be any consult your dealer and do ...

Page 4: ...r supply immediately Have a qualified engineer inspect for safety before operating If the device has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperature If your Showtec device fails to work properly discontinue the use imme...

Page 5: ... 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our announcement that the goods are at their disposal Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of merchan...

Page 6: ...mA Data in out RJ45 connector for Ethernet 3pin XLR for DMX RDM input output Control protocol ArtNet DMX 512 RDM 16 x subnets x 16 universes 256 available DMX RDM universes in a LAN Protecting rate IP20 Operating Temperature 10 C to 50 C Storage Temperature 20 C to 70 C Housing Aluminum Extrusion Dimensions 110 x 67 5 x 42 3 mm LxWxH Weight 0 185 kg Frontside Fig 01 01 DMX RDM IN receives DMX RDM ...

Page 7: ...p your system in the appropriate way This device has two working modes which can be set with the dipswitches If the switches are both off the device will be a DMX RDM in device The device will send DMX to Artnet signals To connect the device with universes and computer see figure 03 If the switches are both on the device will be a DMX RDM out device The device will send Artnet to DMX signals To co...

Page 8: ...7 Ordercode 50802 Node 1 Connections Fig 03 Fig 04 ...

Page 9: ...8 Ordercode 50802 Node 1 Fig 05 ...

Page 10: ...d during the inspection 01 All screws used for installing the device or parts of the device have to be tightly connected and must not be corroded 02 There may not be any deformations on housings fixations and installation spots 03 Mechanically moving parts like axles eyes and others may not show any traces of wearing 04 The electric power supply cables must not show any damages or material fatigue...

Page 11: ...n the controller and the first fixture on the link Fixtures reset correctly but some respond erratically or not at all to the controller Poor data quality Check data quality If much lower than 100 percent the problem may be a bad data link connection poor quality or broken cables missing termination plug or a defective fixture disturbing the link Bad data link connection Inspect connections and ca...

Page 12: ...ses in a LAN Signal input RJ45 3 pin XLR for DMX RDM IN Signal output 3 pin XLR for DMX RDM OUT Control ArtNet DMX 512 RDM Electro mechanical effects Housing Aluminum Extrusion Connections DC5V Data connectors IP rating IP20 Operating Temperature 10 C to 50 C Storage Temperature 20 C to 70 C Minimum distance Minimum distance from flammable surfaces 0 5 m Minimum distance to lighted object 1 m Dime...

Page 13: ...12 Ordercode 50802 Node 1 Notes ...

Page 14: ...13 Ordercode 50802 Node 1 ...

Page 15: ...14 Ordercode 50802 Node 1 ...

Page 16: ... 2016 Showtec ...

Reviews: