RM0082
Miscellaneous registers (Misc)
Doc ID 018672 Rev 1
267/844
12.5 Miscellaneous
register global space
12.5.1 Overview
The global space controls the following functionalities:
●
General purpose input signals:
–
General status/command interface received from programmable logic.
–
Registered input mail box data.
●
General purpose output signals:
–
General output command interface.
–
Programmable logic configuration extension.
–
Registered output mail box data.
Table 201.
PLGPIO4_PAD_PRG register bit assignments
PLGPIO4_PAD_PRG
0x140
Bit
Name
Reset
Value
Description
[31:25]
RFU
-
Reserved for future use (Read return zeros)
[24]
PDN_CLK4
1’h1
Pull down control for pads CLK4
[23]
PUP_CLK4
1’h0
Pull up control for pads CLK4
[22:21]
DRV_CLK4[1:0]
2’h0
Drive strength control for pads CLK4
[20]
SLEW_CLK4
1’h0
Slew control for pads CLK4
[19]
PDN_CLK3
1’h1
Pull down control for pads CLK3
[18]
PUP_CLK3
1’h0
Pull up control for pads CLK3
[17:16]
DRV_CLK3[1:0]
2’h0
Drive strength control for pads CLK3
[15]
SLEW_CLK3
1’h0
Slew control for pads CLK3
[14]
PDN_CLK2
1’h1
Pull down control for pads CLK2
[13]
PUP_CLK2
1’h0
Pull up control for pads CLK2
[12:11]
DRV_CLK2[1:0]
2’h0
Drive strength control for pads CLK2
[10]
SLEW_CLK2
1’h0
Slew control for pads CLK2
[09]
PDN_CLK1
1’h1
Pull down control for pads CLK1
[08]
PUP_CLK1
1’h0
Pull up control for pads CLK1
[07:06]
DRV_CLK1[1:0]
2’h0
Drive strength control for pads CLK1
[05]
SLEW_CLK1
1’h0
Slew control for pads CLK1 & pads 96,97
[04]
PDN_24
1’h1
Pull Down control for pads 96,97
[03]
PUP_24
1’h0
Pull up control for pads 96,97
[02:01]
DRV_24[1:0]
2’h0
Drive Strength control for pads 96,97
[00]
RFU
Reserved for future purpose