![Rohde & Schwarz SMBV100A Operating Manual Download Page 721](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735721.webp)
Remote Control Commands
R&S
®
SMBV100A
706
Operating Manual 1176.8016.02 ─ 17
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:BB:MCCW:TRIGger:SLENgth
<SLength>
Sets the length of the signal sequence to be output in the "Single" trigger mode. The
input is to be expressed in samples. It is then possible to output deliberately just part of
the waveform, an exact sequence of the waveform, or a defined number of repetitions
of the waveform.
Parameters:
<SLength>
integer
Range:
1 to 1000
*RST:
1
Example:
SOURBB:MCCW:SEQ SING
sets trigger mode Single.
SOURBB:MCCW:TRIG:SLEN 200
sets a sequence length of 200 samples. The first 200 samples of
the current waveform will be output after the next trigger event.
Manual operation:
See
[:SOURce<hw>]:BB:MCCW:TRIGger:SOURce
<Source>
Selects the trigger source.
Parameters:
<Source>
INTernal|EXTernal
INTernal
manual trigger or
*TRG
.
EXTernal
trigger signal on the TRIG connector.
*RST:
INTernal
Example:
SOURce1:BB:MCCW:TRIGger:SOURce EXTernal
sets external triggering via the TRIGGER connector.
Manual operation:
See
[:SOURce<hw>]:BB:MCCW:TRIGger[:EXTernal<ch>]:DELay
<Delay>
Specifies the trigger delay (expressed as a number of samples) for external triggering.
Parameters:
<Delay>
float
Range:
0 to 65535
Increment: 0.01
*RST:
0
SOURce Subsystem