![Rohde & Schwarz SMBV100A Operating Manual Download Page 677](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735677.webp)
Remote Control Commands
R&S
®
SMBV100A
662
Operating Manual 1176.8016.02 ─ 17
Parameters:
<Mode>
CLISt | PULSe | PATTern | RATio | TRIGger
CLISt
A marker signal that is defined in the selected control list is gen-
erated.
PULSe
A pulsed marker signal is generated. The pulse frequency (=
symbol rate/divider) is defined with the
SOUR:BB:DM:TRIG:OUTP:PULSe:DIVider
command and
can be queried with the
SOUR:BB:DM:TRIG:OUTP:PULSe:FREQuency?
command.
PATTern
A marker signal is generated with the aid of a user-definable bit
pattern. The bit pattern is entered with the aid of command
SOURce:BB:DM:TRIGger:OUTPut:PATTern
. The bit pattern
is a maximum of 32 bits long.
RATio
A regular marker signal corresponding to the Time Off / Time On
specifications in the commands
SOURce:BB:DM:TRIGger:OUTPut:OFFT
and
SOURce:BB:DM:TRIGger:OUTPut:ONT
is generated.
TRIGger
A received internal or external trigger signal is output at the
marker connector.
*RST:
RATio
Example:
BB:DM:TRIG:OUTP2:MODE PULS
selects the pulsed marker signal on output MARKER 2.
Manual operation:
See
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:OFFTime
<OffTime>
Sets the number of symbols in a period (ON time + OFF time) during which the marker
signal in setting
SOURce:BB:DM:TRIGger:OUTPut:MODE RATio
on the marker out-
puts is OFF.
Parameters:
<OffTime>
integer
Range:
1 to 16777215
*RST:
1
Default unit: symbol
Example:
BB:DM:TRIG:OUTP2:OFFT 20
sets an OFF time of 20 symbols for marker signal 2.
Manual operation:
See
SOURce Subsystem