![Rohde & Schwarz SMBV100A Operating Manual Download Page 732](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735732.webp)
Remote Control Commands
R&S
®
SMBV100A
717
Operating Manual 1176.8016.02 ─ 17
The external baseband signal A can be routed to path A, path B, or both paths. The
external baseband signal B can be routed to path B only.
[:SOURce<hw>]:BBIN:ALEVel:EXECute
.......................................................................... 717
.....................................................................................717
.......................................................................................717
[:SOURce<hw>]:BBIN:DIGital:ASETting:STATe
................................................................ 718
.......................................................................................718
[:SOURce<hw>]:BBIN:IQSWap[:STATe]
.......................................................................... 718
......................................................................................719
[:SOURce<hw>]:BBIN:OLOad:HOLD:RESet
.....................................................................719
[:SOURce<hw>]:BBIN:OLOad:HOLD:STATe?
.................................................................. 719
[:SOURce<hw>]:BBIN:OLOad:STATe?
............................................................................ 720
............................................................................... 720
............................................................................... 720
[:SOURce<hw>]:BBIN:SRATe[:ACTual]
............................................................................721
[:SOURce<hw>]:BBIN:SRATe:FIFO[:STATus]?
.................................................................721
[:SOURce<hw>]:BBIN:SRATe:SOURce
........................................................................... 721
......................................................................................... 722
[:SOURce<hw>]:BBIN:ALEVel:EXECute
This command starts measuring the input signal. The measurement estimates the
crest factor and the peak power.
Example:
BBIN:ALEV:EXEC
starts measuring the input signal.
Usage:
Event
Manual operation:
See
[:SOURce<hw>]:BBIN:CDEVice?
Digital Input only.
Indicates the ID of an externally connected R&S Instrument or R&S Device.
Return values:
<CDevice>
string
Example:
BBIN:CDEV
queries the connected device ID.
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:BBIN:CFACtor
<CFactor>
This command enters the crest factor of the external baseband signal.
SOURce Subsystem