![Rohde & Schwarz SMBV100A Operating Manual Download Page 446](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735446.webp)
Instrument Function
R&S
®
SMBV100A
431
Operating Manual 1176.8016.02 ─ 17
Carrier Graph
Calls a graphical representation of the current multi carrier configuration in the fre-
quency domain.
The height of the bars corresponds to the chosen gain of each individual carrier. The
bandwidth of the carriers signals is indicated by the width of the bars.
Output Settings
The "Output Settings" section in the multi carrier main menu indicates the name, the
size and the clock rate of the currently calculated multi carrier output file.
File
Opens the "File" menu, where the output file name of the multi carrier waveform which
has to be calculated can be entered.
The multi carrier waveform is calculated and saved under this name by clicking the
"Create" or "Create and Load" button.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:OFILe
Clock Rate
Displays the resulting sample rate at which the multi carrier waveform is output by the
arbitrary waveform generator. The output clock rate depends on the number of carri-
ers, carrier spacing and input sample rate of the leftmost or rightmost carriers.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CLOCk?
File Size
Displays the resulting number of samples of the multi carrier waveform.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:SAMPles?
Create
Creates a new multi carrier waveform defined by the multi carrier table and General
Setting entries.
Baseband Signal - Baseband Block