![Rohde & Schwarz SMBV100A Operating Manual Download Page 838](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735838.webp)
Remote Control Commands
R&S
®
SMBV100A
823
Operating Manual 1176.8016.02 ─ 17
Example:
SYST:ERR:ALL?
queries all entries in the error queue.
Response: 0, 'no error'
No errors have occurred since the error queue was last read out.
Usage:
Query only
:SYSTem:ERRor:CODE:ALL?
Queries all entries in the error queue and then deletes them. Only the error numbers
are returned and not the entire error text.
Return values:
<All>
string
0
"No error", i.e. the error queue is empty
positive value
Positive error numbers denote device-specific errors
negative value
Negative error numbers denote error messages defined by
SCPI.
Example:
SYST:ERR:CODE:ALL
queries all entries in the error queue.
Response: 0
no errors have occurred since the error queue was last read out.
Usage:
Query only
:SYSTem:ERRor:CODE[:NEXT]?
Queries the oldest entry in the error queue and then deletes it. Only the error number
is returned and not the entire error text.
Return values:
<Next>
string
0
"No error", i.e. the error queue is empty
positive value
Positive error numbers denote device-specific errors
negative value
Negative error numbers denote error messages defined by
SCPI.
Example:
SYST:ERR:CODE
queries the oldest entry in the error queue.
Response: 0
No errors have occurred since the error queue was last read out.
Usage:
Query only
SYSTem Subsystem