![Rohde & Schwarz SMBV100A Operating Manual Download Page 702](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735702.webp)
Remote Control Commands
R&S
®
SMBV100A
687
Operating Manual 1176.8016.02 ─ 17
Parameters:
<Mode>
IQ | VECTor | CCDF | PSPectrum | CONStellation | EYEI |
EYEQ
*RST:
IQ
Example:
BB:GRAP:MODE VECT
selects vector diagram.
Manual operation:
See
[:SOURce<hw>]:BB:GRAPhics:SMARt:STATe
<State>
Activates/deactivates the "smart graphics".
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
BB:GRAP:SMAR:STAT ON
Activates smart graphics.
Manual operation:
See
[:SOURce<hw>]:BB:GRAPhics:SRATe:MODE
<Mode>
Sets how the time resolution of the signal is determined. Maximum resolution corre-
sponds to a display covering the entire signal bandwidth. The higher the resolution is,
the shorter the length of the displayed signal segment will be for the specified record-
ing depth.
Parameters:
<Mode>
AUTO | FULL | USER
AUTO
The resolution is set to an optimum value on the basis of the sig-
nal and display type.
FULL
The resolution is set such that the display covers the entire sig-
nal bandwidth.
USER
with the command
SOUR:BB:GRAP:SRAT:USER
, the user can
determine the resolution by setting the signal bandwidth for
which the display is to be generated
*RST:
AUTO
Example:
BB:GRAP:SRAT:MODE FULL
sets the sample rate mode.
Manual operation:
See
SOURce Subsystem