![Rohde & Schwarz SMBV100A Operating Manual Download Page 669](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735669.webp)
Remote Control Commands
R&S
®
SMBV100A
654
Operating Manual 1176.8016.02 ─ 17
Parameters:
<Mode>
NONE | MASTer | SLAVe
NONE
The instrument is working in stand-alone mode.
MASTer
The instrument provides all connected instrument with its syn-
chronisation (including the trigger signal) and reference clock
signal.
SLAVe
The instrument receives the synchronisation and reference clock
signal from another instrument working in a master mode.
*RST:
NONE
Example:
BB:DM:CLOC:SYNC:MODE MAST
the instrument is configured to work as a master one.
Manual operation:
See
[:SOURce<hw>]:BB:DM:CLOCk:SYNChronization:EXECute
Performs automatically adjustment of the instrument's settings required for the syn-
chronization mode, set with the command
BB:DM:CLOC:SYNC:MODE
.
Example:
BB:DM:CLOC:SYNC:MODE MAST
the instrument is configured to work as a master one.
BB:DM:CLOC:SYNC:EXEC
all synchronization's settings are adjusted accordingly.
Usage:
Event
Manual operation:
See
"Set Synchronization Settings"
Trigger Settings
The numeric suffix to
OUTPut
distinguishes between the available markers.
[:SOURce<hw>]:BB:DM:TRIGger:ARM:EXECute
.............................................................. 655
[:SOURce<hw>]:BB:DM:TRIGger:EXECute
...................................................................... 655
[:SOURce<hw>]:BB:DM:TRIGger:EXTernal:SYNChronize:OUTPut
.....................................655
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut:DELay:FIXed
....................................................656
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:DELay
...................................................... 657
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:DELay:MINimum?
..................................... 657
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:DELay:MAXimum?
.................................... 657
[:SOURce<hw>]:BB:DM:TRIGger:RMODe?
...................................................................... 657
[:SOURce<hw>]:BB:DM:TRIGger:SLENgth
.......................................................................658
[:SOURce<hw>]:BB:DM:TRIGger:SOURce
.......................................................................658
[:SOURce<hw>]:BB:DM:TRIGger:DELay:UNIT
................................................................. 659
[:SOURce<hw>]:BB:DM:TRIGger[:EXTernal<ch>]:DELay
.................................................. 659
[:SOURce<hw>]:BB:DM:TRIGger[:EXTernal]:TDELay
........................................................660
SOURce Subsystem