![Rohde & Schwarz SMBV100A Operating Manual Download Page 832](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735832.webp)
Remote Control Commands
R&S
®
SMBV100A
817
Operating Manual 1176.8016.02 ─ 17
If you change the step size, the number of steps changes accordingly. The sweep
range remains the same.
Parameters:
<Logarithmic>
float
Increment: 0.01
*RST:
1
Example:
SWE:POW:STEP 10dB
sets the step width for logarithmic sweep spacing to 10 dB of the
previous level in each instance (for a level sweep).
Manual operation:
See
[:SOURce<hw>]:SWEep:RESet[:ALL]
Resets all active sweeps to the starting point.
Example:
SWE:RES
resets all active sweeps to the starting point.
Usage:
Event
Manual operation:
See
7.17 STATus Subsystem
This system contains the commands for the status reporting system. See also
ter 6.5, "Status Reporting System"
on page 494 for detailed information.
on page 507 has no effect on the status registers.
Value ranges
●
Queries return the current value of the respective register, which permits a check of
the device status.
Return values: A decimal value in the range 0 to 32767 (=2
15
-1)
●
The configuration commands set the respective register thus determining which
status changes of the R&S
SMBV cause the status registers to be changed.
Setting values: A decimal value in the range 0 to 32767 (=2
15
-1)
...................................................................................... 818
.......................................................................................... 818
.......................................................................................... 818
....................................................................................818
.................................................................................... 819
:STATus:QUEStionable:CONDition
..................................................................................819
...................................................................................... 819
......................................................................................820
STATus Subsystem