![Rohde & Schwarz SMBV100A Operating Manual Download Page 621](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735621.webp)
Remote Control Commands
R&S
®
SMBV100A
606
Operating Manual 1176.8016.02 ─ 17
For two or more R&S SMBVs configured to work in a master-slave mode for synchro-
nous signal generation:
●
disable this parameter in the slave instruments, in case the master instrument pro-
vides the slaves with its internal trigger signal and
●
use the default enabled state, if a common external trigger event is provided for the
master and the slave instruments.
Parameters:
<Output>
0 | 1 | OFF | ON
ON
The signal calculation starts simultaneously with the external
trigger event but because of the instrument’s processing time
the first samples are cut off and no signal is outputted. After
elapsing of the internal processing time, the output signal is syn-
chronous to the trigger event.
OFF
The signal output begins after elapsing of the processing time
and starts with sample 0, i.e. the complete signal is outputted.
This mode is recommended for triggering of short signal sequen-
ces with signal duration comparable with the processing time of
the instrument.
*RST:
ON
Example:
BB:ARB:TRIG:SOUR EXT
sets external triggering.
BB:ARB:TRIG:EXT:SYNC:OUTP ON
enables synchronous output to external trigger
Manual operation:
See
"Sync. Output to External Trigger"
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:DELay:MAXimum?
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:DELay:MINimum?
The command queries the minimum marker delay for set-
ting
:BB:ARB:TRIGger:OUTPut:DELay:FIXed ON
.
Return values:
<Minimum>
float
Range:
0 to 16777215
Increment: 1E-3
*RST:
0
Example:
BB:ARB:TRIG:OUTP:DEL:FIX ON
restricts the marker signal delay setting range to the dynamic
range.
BB:ARB:TRIG:OUTP:DEL:MIN
queries the minimum of the dynamic range.
Response: 0
the minimum for the marker delay setting is 0 samples.
Usage:
Query only
SOURce Subsystem