![Rohde & Schwarz SMBV100A Operating Manual Download Page 672](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735672.webp)
Remote Control Commands
R&S
®
SMBV100A
657
Operating Manual 1176.8016.02 ─ 17
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:DELay
<Delay>
Defines the delay between the signal on the marker outputs and the start of the signal,
expressed in terms of symbols. Command
can be used to restrict the range of values to the dynamic
range, i.e. the range within which a delay of the marker signals can be set without
restarting the marker and signal.
Parameters:
<Delay>
float
Range:
0 to 16777215
Increment: 0.001
*RST:
0
Example:
BB:DM:TRIG:OUTP2:DEL 16
sets a delay of 16 symbols for the signal on connector MARKER
2.
Manual operation:
See
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:DELay:MINimum?
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:DELay:MAXimum?
Queries the maximum marker delay for setting
:BB:DM:TRIG:OUTP:DEL:FIX ON
.
Return values:
<Maximum>
float
Range:
0 to 16777215
Increment: 1E-3
*RST:
2000
Example:
BB:DM:TRIG:OUTP:DEL:FIX ON
restricts the marker signal delay setting range to the dynamic
range.
BB:DM:TRIG:OUTP:DEL:MAX
queries the maximum of the dynamic range.
Response: 2000
the maximum for the marker delay setting is 2000 symbols.
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:BB:DM:TRIGger:RMODe?
Queries the status of signal generation for all trigger modes with digital modulation on.
SOURce Subsystem