Parameters:
<Angle>
float
Range:
0 to 180
Increment: 0.01
*RST:
0
Default unit: Deg
Example:
BB:DM:FORM AQPS
selects modulation type AQPSK.
BB:DM:AQPS:ANGL 45
Manual operation:
See
[:SOURce<hw>]:BB:DM:ASK:DEPTh
<Depth>
The command sets the ASK modulation depth when modulation type ASK is selected.
Parameters:
<Depth>
float
Range:
0 to 100
Increment: 0.1
*RST:
100
Default unit: PCT
Example:
BB:DM:FORM ASK
selects the ASK modulation type.
BB:DM:ASK:DEPT 50 PCT
sets a modulation depth of 50 percent.
Manual operation:
See
[:SOURce<hw>]:BB:DM:CODing
<Coding>
The command selects the modulation coding.
If the modulation type selected (
:BB:DM:FORM
) is not possible with the coding that has
been set, it is automatically set to OFF (
:BB:DM:COD OFF
).
When a standard is selected (
:BB:DM:STAN
), the coding is set to the default value.
Parameters:
<Coding>
OFF | DIFF | DPHS | DGRay | GRAY | GSM | NADC | PDC |
PHS | TETRa | APCO25 | PWT | TFTS | INMarsat | VDL |
EDGE | APCO25FSK | ICO | CDMA2000 | WCDMA |
APCO258PSK
DPHS
Phase Difference
DGRay
Diff Gray
*RST:
INTernal
SOURce Subsystem