![Rohde & Schwarz SMBV100A Operating Manual Download Page 628](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735628.webp)
Remote Control Commands
R&S
®
SMBV100A
613
Operating Manual 1176.8016.02 ─ 17
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:PATTern
<Pattern>,
<BitCount>
The command defines the bit pattern used to generate the marker signal.
Parameters:
<Pattern>
numeric
0 is marker off, 1 is marker on.
*RST:
#H2
<BitCount>
integer
Range:
1 to 64
*RST:
2
Example:
BB:ARB:TRIG:OUTP:MODE PATT
BB:ARB:TRIG:OUTP:PATT #H39FE0000,32
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:PULSe:DIVider
<Divider>
The command sets the divider for the pulsed marker signal in the setting
SOURce:BB:ARB:TRIGger:OUTPut:MODE PULSe
. The pulse frequency is derived
by dividing the symbol rate by the divider.
Parameters:
<Divider>
integer
Range:
2 to 1024
*RST:
2
Example:
BB:ARB:TRIG:OUTP2:PULS:DIV 2
sets the divider for the marker signal on output MARKER 2 to
the value 2.
BB:ARB:TRIG:OUTP2:FREQ?
queries the resulting pulse frequency of the marker signal
Response: 66 000
the resulting pulse frequency is 66 kHz.
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:PULSe:FREQuency?
The command queries the pulse frequency of the pulsed marker signal in the setting
SOURce:BB:ARB:TRIGger:OUTPut:MODE PULSe
. The pulse frequency is derived
by dividing the symbol rate by the divider. The divider is defined with com-
mand
:BB:ARB:TRIG:OUTP:PULS:DIV
.
Return values:
<Frequency>
float
Increment: 0.001
SOURce Subsystem