![Rohde & Schwarz SMBV100A Operating Manual Download Page 719](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735719.webp)
Remote Control Commands
R&S
®
SMBV100A
704
Operating Manual 1176.8016.02 ─ 17
Example:
BB:MCCW:TRIG:SOUR INT
sets internal triggering.
BB:MCCW:TRIG:SEQ RETR
sets Retrigger mode, i.e. every trigger event causes signal gen-
eration to restart.
BB:MCCW:TRIG:EXEC
executes a trigger.
Usage:
Event
Manual operation:
See
[:SOURce<hw>]:BB:MCCW:TRIGger:EXTernal:SYNChronize:OUTPut
<Output>
(enabled for Trigger Source External)
Enables/disables output of the signal synchronous to the external trigger event.
"Sync. Output to External Trigger"
on page 446 for a detailed descrip-
tion of the applications of this setting.
Parameters:
<Output>
0 | 1 | OFF | ON
ON
The signal calculation starts simultaneously with the external
trigger event but because of the instrument's processing time
the first samples are cut off and no signal is outputted. After
elapsing of the internal processing time, the output signal is syn-
chronous to the trigger event.
OFF
The signal output begins after elapsing of the processing time
and starts with sample 0, i.e. the complete signal is outputted.
This mode is recommended for triggering of short signal sequen-
ces with signal duration comparable with the processing time of
the instrument.
*RST:
1
Example:
BB:MCCW:TRIG:SOUR EXT
sets external triggering.
BB:MCCW:TRIG:EXT:SYNC:OUTP ON
enables synchrounous output to external trigger.
Manual operation:
See
"Sync. Output to External Trigger"
[:SOURce<hw>]:BB:MCCW:TRIGger:OBASeband:DELay
<Delay>
Sets the trigger delay for external triggering.
SOURce Subsystem