[:SOURce<hw>]:AWGN:POWer:SUM:PEP?
In Additive Noise and CW Interferer (
SOUR:AWGN:MODE ADD|CW
) modes, queries the
peak envelope power of the overall signal comprised of noise signal plus useful signal.
Return values:
<Pep>
float
Range:
-145 to 20
Increment: 0.01
*RST:
0
Example:
SOURce:AWGN:POWer:SUM:PEP?
queries the peak envelope power of the overall signal.
Usage:
Query only
Manual operation:
See
" C Noise PEP / Noise PEP (Total Band-
width) / C Interferer PEP / Interferer PEP "
[:SOURce<hw>]:AWGN:STATe
<State>
Activates or deactivates the white noise (AWGN = Averaged White Gaussian Noise).
Use the command
to define the mode the AWGN gen-
erator is working in.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
SOURce:AWGN:STATe ON
Manual operation:
See
7.16.3 SOURce:BB Subsystem
This subsystem contains all commands for digital signal generation. It is divided into
several subsystems which are described separately.
OUTPut<ch>
The numeric suffix to
OUTPut
distinguishes between the available markers.
Only two markers are available for the R&S SMBV, i.e. the allowed values for the suffix
are 1 or 2.
EXTernal<ch>
The numeric suffix to
EXTernal
distinguishes between the available external trigger
inputs.
SOURce Subsystem