![Rohde & Schwarz SMBV100A Operating Manual Download Page 638](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735638.webp)
Remote Control Commands
R&S
®
SMBV100A
623
Operating Manual 1176.8016.02 ─ 17
Parameters:
<Reference>
RMS | PEAK
*RST:
RMS
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CARRier<ch>:STATe
<State>
Enables/disables the selected carrier.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
SOURce1:BB:ARBitrary:MCARrier:CARRier15:STATe
ON
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CFACtor:MODE
<Mode>
The command sets the mode for optimizing the crest factor by calculating the carrier
phases.
Parameters:
<Mode>
OFF | MIN | MAX
OFF
There is no automatic setting for minimizing or maximizing the
crest factor. The Phase setting (command
BB:ARB:MCAR:CARR:PHAS
) is in use.
MIN
The crest factor is minimized by internally calculating optimized
carrier phases. The Phase setting (command
BB:ARB:MCAR:CARR:PHAS
) is invalid.
MAX
The crest factor is maximized by internally calculating optimized
carrier phases. The Phase setting (command
BB:ARB:MCAR:CARR:PHAS
) is invalid.
*RST:
OFF
Example:
BB:ARB:MCAR:CFAC:MODE OFF
switches off automatic crest factor optimization. The setting
SOUR:BB:ARB:MCAR:CARR:PHAS
has an effect.
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CLIPping:CFACtor
<CFactor>
Sets the value of the desired crest factor, if baseband clipping is enabled
(
BB:ARB:MCAR:CLIP:STAT ON
).
SOURce Subsystem