vlan 50 smart
port vlan 50 0/0 0
port vlan 50 0/0 1
link-aggregation 0/0 0 0/0 1 egress-ingress workmode lacp-static
vdsl line-profile quickadd 3 snr 60 0 300 60 0 300
vdsl channel-profile quickadd 3 path-mode atm interleaved-delay 8 2 inp 4 2 rate
128 10000 128 10000 2048 2048
interface vdsl 0/1
deactivate 0
activate 0 template-index 3
alarm-config 0 1
quit
service-port 3 vlan 50 vdsl mode atm 0/1/0 vpi 1 vci 39 inbound traffic-table index
5 outbound traffic-table index 5
service-port desc 3 description MA5616HW/Vlanid:50/vdsl/smart
mac-address max-mac-count service-port 3 16
mac-pool xpoa 0000-1111-1010 300
pppoa enable
encapsulation 0/1/0 vpi 1 vci 39 type pppoa llc
pitp enable pmode
raio-mode cntel pitp-pmode
save
9.1.4 Configuration Example of the xDSL IPoA Internet Access
Service
This topic describes how to configure a user so that the user can access the MA5616 in the xDSL
mode, and then access the Internet in the IPoA mode at a rate of 2048 kbit/s.
Service Requirements
l
The user accesses the Internet in the IPoA mode. The MA5616 works in the L2 mode.
l
User packets, which carry a single VLAN tag, are transmitted in the upstream direction,
and the services of multiple users are converged into one VLAN. This is called the N:1
access.
l
The user access rate is 2048 kbit/s, which is restricted by the traffic profile.
l
Dual GE ports are adopted for upstream transmission to ensure reliability. Link aggregation
is configured for the two upstream ports.
shows an example network of the xDSL IPoA Internet access service.
Figure 9-4
Example network of the xDSL IPoA Internet access service
SmartAX MA5616 Multi-service Access Module
Configuration Guide
9 Configuration Example of Services on the MA5616
Through GE Upstream Transmission
Issue 04 (2011-10-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
419