Run the
quit
command to quit the miniesc mode, and then run the
save
command to save the
data.
----End
Result
After the configuration, the ESCM works in the normal state and monitors the analog and digital
parameters set on the MA5616.
l
When an analog parameter measured is not within the upper and lower alarm thresholds
preset in the system, the MA5616 reports an alarm.
l
When the actual level of a monitored digital parameter is different from the valid level
preset in the system, the MA5616 reports an alarm.
Example
shows the data plan for configuring the ESCM.
Table 3-25
Data plan for configuring the ESCM
Item
Data
Remarks
EMU
Type: ESCM (MiniESC)
The ESCM is displayed as
MiniESC
on the CLI.
SN: 3
-
Subnode ID: 8
NOTE
The hardware DIP switch on
the ESCM ranges from 0–15
and therefore the subnode
ID ranges from 0–15.
Ensure that the hardware
DIP switch on the ESCM is
set the same as that of the
EMU subnode on the
device.
This topic uses value 8 as an
example.
The hardware DIP switch on the ESCM is set to
8.
Analog
parameters
Analog parameter ID: 0
This analog parameter is set according to the
actual requirements. The built-in analog
parameter is set here to monitor the ambient
temperature of the device.
For values and details of this parameter, see the
esc analog
command.
Upper alarm threshold of
analog parameter 0: 54°C
When the ambient temperature of the device is
higher than 54°C, the device reports an alarm.
Lower alarm threshold of
analog parameter 0: 6°C
When the ambient temperature of the device is
lower than 6°C, the device reports an alarm.