Measurement Configuration
The sampling rate is automatically set to 1/100 of the selected timebase.
If MR8990 Digital Voltmeter Unit is installed, that channel's sampling rate is automatically set to 1/50 of
the selected timebase.
Example: When 8966 is installed as unit 1 (CH1 and CH2) and MR8990 as unit 2 (CH3 and CH4), and
the timebase is set to 1 s/div
Sampling rate of unit 1 (8966): 10 ms
Sampling rate of unit 2 (MR8990): 20 ms
To automatically set the timebase
When you press the
AUTO
key, a suitable timebase for the input signal is selected and
measurement starts. (This applies only to the Memory Function.)
Refer to “3.6 Measurement With Automatic Range Setting (Auto-ranging Function)” (p. 70).
• The timebase and sampling rate can be set independently. The sampling rate is selected depending on
the timebase setting.
• When the following timebase values are selected, displayed waveforms are compressed in the
horizontal (time axis) direction as shown.
20 ms/div →
×1/2,
10 ms/div →
×1/5
To minimize noise during measurement
If the sampling rate is too fast and the input waveform amplitude is small, the difference between
maximum and minimum values may become quite large as a result of sudden fluctuations, such
as those caused by noise. To prevent this, select a slower sampling rate or enable the module's
Common
The data refresh rate is not allowed to exceed the maximum sampling rate of the module.
During the period when data is not updated, the same data is measured, resulting in a stair-shaped
waveform.
Even when the same signal is sampled simultaneously by two modules, the data may differ due to
differences in sampling rate, frequency bandwidth, and frequency response.
Data refresh rate for various modules
Module
Max. timebase
Max. sampling rate
Reference
Model 8966
5 µs/div
50 ns (20 MS/s)
-
Model 8967
Dependent on data refresh
setting
Dependent on data refresh
setting
Model 8968
100 µs/div
1 µs (1 MS/s)
-
Model 8969
Model U8969
500 µs/div
5 µs (200 kS/s)
-
Model 8970
Dependent on setting
Dependent on setting
Model 8971
100 µs/div
1 µs (1 MS/s)
Model 8972
Dependent on response
setting
Dependent on response
setting
Model 8973
5 µs/div
50 ns (20 MS/s)
-
Model MR8990 Dependent on NPLC setting Dependent on NPLC setting
Model U8974
100 µs/div
1 µs (1 MS/s)
Summary of Contents for MR8827
Page 19: ...14 Operation Precautions ...
Page 81: ...76 Start and Stop Measurement ...
Page 111: ...106 Manage Files ...
Page 125: ...120 Miscellaneous Printing Functions ...
Page 143: ...138 View Block Waveforms ...
Page 191: ...186 Setting Output Waveform Parameters ...
Page 291: ...286 FFT Analysis Modes Measurable Ranges With Octave Analysis 1 1 OCT 1 3 OCT ...
Page 292: ...287 FFT Analysis Modes 1 1 OCT 1 3 OCT 13 FFT Function ...
Page 293: ...288 FFT Analysis Modes 1 1 OCT 1 3 OCT ...
Page 295: ...290 FFT Analysis Modes ...
Page 309: ...304 Editor Command Details ...
Page 387: ...382 Module Specifications ...
Page 405: ...400 Dispose of the Instrument Lithium Battery Removal ...
Page 431: ...A26 FFT Definitions ...
Page 436: ......