Common Functions
18.2 Common Functions
Modules, Waveform Display
Measurement mode
Depends on module used
Measurement range
Depends on module used
Input coupling
Depends on module used
Low-pass filter
Depends on module used
Displayed graphs
Displayed graph setting with multi-screen and multi-printing function enabled (up to 16
graphs)
Waveform display
Off or selectable from among 16 colors
Printer density
4 levels
Waveform display
position
In increments of 1%
Preset (ascending, descending, 0%, 50%)
Zero adjust
All channels and ranges together
Waveform display
magnification
Horizontal axis (Time axis): ×10, ×5, ×2, ×1, ×1/2, ×1/5, ×1/10, ×1/20, ×1/50, ×1/100,
×1/200, ×1/500, ×1/1000, ×1/2000, ×1/5000, ×1/10000,
×1/20000 (expansion only with Memory function)
Vertical axis (Voltage axis): ×100, ×50, ×20, ×10, ×5, ×2, ×1, ×1/2, ×1/5, ×1/10
Variable display
function
Specified by upper and lower limit values, by displayed amplitude per division
Scaling
Automatic scaling (10:1, 100:1, 1000:1, Various probes selectable)
Manual scaling (conversion ratio setting, two-point setting and unit settings)
Invert function
Polarity reversal
Vernier function
Included
Commenting
Alphanumeric and Japanese characters (title for each analog and logic channel)
Comment entry
method
Simple input by using the keys of the Memory HiCorder, mouse, and keyboard
Stored string and historical string entry (pre-stored and previously used strings can be
recalled, inserted and edited)
Copy channel
settings
Copy and paste, or paste all
Logic setting
Width:
Selectable from three types: wide, standard, and narrow
Display position: Freely settable in increments of 1%
Display bits:
Off or selectable from among 16 colors, settable individually for each bit
Zoom function
The waveform screen is divided vertically in two, and the lower portion displays zoomed
waveforms.
Trigger Function
Trigger method
Digital comparison
Trigger modes
•Memory function, FFT function: Single, Repeat, Automatic
•Recorder function: Single, Repeat
Trigger source
Analog Unit (CH1 to CH32), Standard Logic 32 Channels
Independent trigger criteria settable for each channel
Free-run operation occurs when all trigger types are off.
External Trigger occurs by applying a 2.5 V falling edge signal, shorted terminals
Manual trigger, Timer trigger
Trigger criteria
AND or OR of each trigger source
Summary of Contents for MR8827
Page 19: ...14 Operation Precautions ...
Page 81: ...76 Start and Stop Measurement ...
Page 111: ...106 Manage Files ...
Page 125: ...120 Miscellaneous Printing Functions ...
Page 143: ...138 View Block Waveforms ...
Page 191: ...186 Setting Output Waveform Parameters ...
Page 291: ...286 FFT Analysis Modes Measurable Ranges With Octave Analysis 1 1 OCT 1 3 OCT ...
Page 292: ...287 FFT Analysis Modes 1 1 OCT 1 3 OCT 13 FFT Function ...
Page 293: ...288 FFT Analysis Modes 1 1 OCT 1 3 OCT ...
Page 295: ...290 FFT Analysis Modes ...
Page 309: ...304 Editor Command Details ...
Page 387: ...382 Module Specifications ...
Page 405: ...400 Dispose of the Instrument Lithium Battery Removal ...
Page 431: ...A26 FFT Definitions ...
Page 436: ......