375
Module Specifications
18.6.11
U8793 Arbitrary Waveform Generator Unit
General Specifications
Operating
environment
As per Memory HiCorder in which Model U8793 is installed
Operating
temperature and
humidity
As per Memory HiCorder in which Model U8793 is installed
Storage temperature
and humidity
-20°C to 50°C (-4°F to 122°F), 80% RH or less (no condensation)
Standards
Safety EN61010
EMC
EN61326 Class A
Dimensions
Approx. 106W × 19.8H × 196.5D mm (4.17″W × 0.78″H × 7.74″D) (excluding protrusions)
Mass
Approx. 250 g (8.8 oz.)
Product warranty
period
3 years
Options
Model L9795-01 Connection Cable (terminal type: SMB terminal/mini-alligator clip)
Model L9795-02 Connection Cable (terminal type: SMB terminal/BNC terminal)
Output Specifications
Basic Specifications (common for FG function and arbitrary waveform generation function)
Conditions of
guaranteed accuracy
Guaranteed accuracy period: 1 year
Guaranteed accuracy period from adjustment made by Hioki: 1 year
Temperature and humidity for guaranteed accuracy: 23°C±5°C (73°F±9°F), 80% RH or less
Warm-up time: at least 30 min.
Power supply frequency range for Memory HiCorder in which Model U8793 is installed:
50 Hz/60 Hz±2 Hz
Number of output
channels
2 channels
Output terminals
SMB terminals
Output type
Unbalanced output (floating)
Maximum rated
voltage to earth
33 V rms AC or 70 V DC
(between individual output channels and enclosure/external I/O terminals as well as
between individual output channels)
Anticipated transient overvoltage: 330 V
Maximum output
voltage
-10 V to 15 V
Amplitude setting
range
0 V p-p to 20 V p-p (setting resolution: 1 mV)
DC offset
setting range
-10 V to 15 V (setting resolution: 1 mV)
Output impedance
1
Ω
or less
Maximum output
current
±10 mA (per channel)
Allowable load
resistance
1.5 k
Ω
or greater
Output format
Waveform output/open/short
Specifications
18
Summary of Contents for MR8827
Page 19: ...14 Operation Precautions ...
Page 81: ...76 Start and Stop Measurement ...
Page 111: ...106 Manage Files ...
Page 125: ...120 Miscellaneous Printing Functions ...
Page 143: ...138 View Block Waveforms ...
Page 191: ...186 Setting Output Waveform Parameters ...
Page 291: ...286 FFT Analysis Modes Measurable Ranges With Octave Analysis 1 1 OCT 1 3 OCT ...
Page 292: ...287 FFT Analysis Modes 1 1 OCT 1 3 OCT 13 FFT Function ...
Page 293: ...288 FFT Analysis Modes 1 1 OCT 1 3 OCT ...
Page 295: ...290 FFT Analysis Modes ...
Page 309: ...304 Editor Command Details ...
Page 387: ...382 Module Specifications ...
Page 405: ...400 Dispose of the Instrument Lithium Battery Removal ...
Page 431: ...A26 FFT Definitions ...
Page 436: ......