FibeAir IP-20C/S/E
User Guide
Ceragon Proprietary and Confidential
Page 88 of 597
3.6.5
Editing Standby Unit Settings
Almost all settings of the standby unit are view-only. However, several
settings are editable on the Standby unit. They must be configured separately
for the Standby unit, and are not copied via copy-to-mate, nor do they trigger a
configuration mismatch in the CLI.
In the Web EMS, failure to synchronize these configuration settings causes a
configuration mismatch alarm.
The following settings must be configured separately on the standby unit:
Setting the Unit Name – in the Name field of the Unit Parameters page (see
Configuring Unit Parameters).
Disabling/enabling Radio TX-mute – in the TX mute field of the Edit Radio
Parameters window. Refer to Configuring the Radio Parameters.
Clearing the Radio and RMON counters – in the TX mute field of the
Counters Page. Refer to Displaying and Clearing Defective Block Counters.
Setting the activation key configuration – in the Activation Key and Demo
admin fields of the Activation Key Configuration Page (see Configuring the
Activation Key).
Defining user accounts – Refer to the Access Control User Accounts Page
(see Configuring Users).
Setting synchronization settings – Refer to the SyncE Regenerator
page (see Configuring SyncE Regenerator).
3.6.6
Viewing Link and Protection Status and Activity
You can view link and protection status and activity any time.
To view link and protection status and activity:
1 Select Platform > Management > Unit Redundancy. The Unit
Redundancy (HSB Protection) page opens.
Unit Redundancy Page