Table 125: C-VLAN CoS Preservation Mode CLI Parameters
Parameter
Input Type
Permitted Values
Description
sp-id
Number
1-32 for P2P and MP
services.
1-30 for MNG services.
The Service Point ID.
c-vlan cos
preservation
mode
Variable
enable
disable
Select enable or disable to determine
whether the original C-VLAN CoS value is
preserved or restored for
frames egressing the service point.
enable - the C-VLAN CoS value of
frames egressing the service point is
the same as the value when the
frame entered the service.
disable - the C-VLAN CoS value of
frames egressing the service point is
set at whatever value might have
been re-assigned by the interface,
service point, or service, or whatever
value results from marking (see
Configuring Marking (CLI)).
Examples
The following command enables C-VLAN CoS preservation for Service Point 1
on Service 37:
service[37]>sp cvlan-cos-preservation-mode set spid 1 mode
enable
The following command disables C-VLAN CoS preservation for Service Point 1
on Service 37:
service[37]>sp cvlan-cos-preservation-mode set spid 1 mode
disable
Configuring C-VLAN Preservation (CLI)
To configure VLAN preservation for C-VLAN-tagged frames, go to service view
for the service and enter the following command:
service[SID]>sp cvlan-preservation-mode set spid <sp-id> mode
<c-vlan preservation mode>
Table 126: C-VLAN Preservation CLI Parameters
Parameter
Input Type
Permitted Values
Description
sp-id
Number
1-32 for P2P and MP
services.
1-30 for MNG services.
The Service Point ID.